Pharmaceutical Refractometer
Industry Description For Pharmaceutical Refractometer
Pharmaceutical measurement demands meeting the required standard, for example USP<831>, EP2.2.6 and similar. There is no тАЬgood enoughтАЭ in pharma, additives and formulations must meet USP requirements. Documentation is also key, simply generating a number is not enough. The laboratory has to be able to prove calibration and, when it is operating under 21 CFR 11; document who did the measurement and create an audit trail showing every interaction with the pharmaceutical refractometer. Additionally, the operating software and data security has to be proven to work by an IQOQPQ before acceptance. From a measurement system point of view it is also important that the instrument has the broad range to measure pharmaceuticals. This includes materials like sevoflurane (RI of 1.26) and cinnamon oil (RI of 1.61). A food or even a general chemical refractometer usually does not have sufficient range to cover this.
рд░реВрдбреЛрд▓реНрдл рдХреЛ рдЪреБрдирдиреЗ рдХреЗ рдХрд╛рд░рдг
- Proven 21 CFR 11 system with electronic signature and full audit trail documentation.
- Detailed IQOQPQ using traceable standards across the whole range of the instrument.
- Wide enough range to measure everything in the USP / EP / BP / IP / CP / JP.
рд╡рд┐рд╢рд┐рд╖реНрдЯ рд░реВрдбреЛрд▓реНрдл рдЙрдкрдпреЛрдЧрдХрд░реНрддрд╛
- ┬аReference laboratories like the USP need to be able to measure EVERY material in the Pharmacopeia and find the wide range of the J257 essential.
- GSK, Merck, Pfizer all use the J series for checking incoming raw materials.
- Biogen uses the J series for in process concentration measurement.
рдЙрджреНрдпреЛрдЧ рдХреЗ рдЕрдиреБрд╕рд╛рд░ рд░рд┐рдлреНрд░реИрдХреНрдЯреЛрдореАрдЯрд░ рдХрд╛ рдЪрдпрди
- рдЦрд╛рджреНрдп рдФрд░ рдкреЗрдп рдкрджрд╛рд░реНрде
- рдЪреАрдиреА рдорд┐рд▓рд┐рдВрдЧ, рд╢реЛрдзрди, рдкреНрд░рд╕рдВрд╕реНрдХрд░рдг
- рд░рд╛рд╕рд╛рдпрдирд┐рдХ
- рдФрд╖рдзрд┐ рдФрд░ рд╡рд┐рд╖ рд╡рд┐рдЬреНрдЮрд╛рди рдкрд░реАрдХреНрд╖рдг
- рдкреЗрдЯреНрд░реЛрд▓рд┐рдпрдо
- рд╕реНрд╡рд╛рдж, рдЦреБрд╢рдмреВ, рд╕реМрдВрджрд░реНрдп рдкреНрд░рд╕рд╛рдзрди
- рдореЙрдбрд▓ рддреБрд▓рдирд╛ рдЪрд╛рд░реНрдЯ
- рдЕрдВрд╢рд╛рдВрдХрди рдФрд░ рджрд╕реНрддрд╛рд╡реЗрдЬрд╝реАрдХрд░рдг
J457 an ideal Pharmaceutical Refractometer or Hospital Toxicology Refractometer.
A high accuracy Pharmaceutical refractometer for research, hospital refractometer toxicology testing, compounding, and drug monitoring may require instruments with reliable temperature control, compliance tracking, and specific measurement ranges.┬а Does your application require you to measureтАж
|
|
|
A pharmaceutical refractometer requires specific features
Enflurane, Sevoflurane and similar halogenated ethers are used extensively for the induction and maintenance of general anesthesia. Their manufacture must comply with specifications from the USP/EP or relevant pharmacopeias. Many of these pharmacopeias require the measurement of refractive index. For example, the US Pharmacopeia requires that sevoflurane has a refractive index of 1.2745 тАУ 1.2760 at 20┬░C. For 21 CFR Part 11 compliance choose the 21 CFR Part 11 option.
| рд░рд┐рдлреНрд░реИрдХреНрдЯреЛрдореАрдЯрд░ рдореЙрдбрд▓ | рд╡рд┐рдирд┐рд░реНрджреЗрд╢ | рд╡рд┐рд╢реЗрд╖рддрд╛рдПрдВ рдПрд╡рдВ рд▓рд╛рдн |
|---|---|---|
![]() |
Measurement Range:┬а1.26 тАУ 1.70 RI; 0 тАУ 95% Brix Accuracy:0.0001 RI; 0.1 Brix Electronic Temperature Control:Flexible temperature selection between 15┬░C тАУ 70┬░C |
USP General Subchapter <831> Refractive Index States: тАжAlthough the standard temperature for Pharmacopeial measurements is 25┬░C, many of the refractive index specifications in the individual monographs call for determining this value at 20┬░C. The temperature should be carefully adjusted and maintained, since the refractive index varies with the temperatureтАж тАжTo achieve the theoretical accuracy of ┬▒0.0001, it is necessary to calibrate the instrument against a standard provided by the manufacturer and to check frequently the temperature control and cleanliness of the instrument by determining the refractive index of distilled water, which is 1.3330 at 20┬░C and 1.3325 at 25┬░CтАж The┬аJ357 refractometer provides the refractive index range, accuracy, performance and optional 21 CFR Part 11 compliance demanded by large pharmaceutical firms making this a popular pharmaceutical refractometer. |
![]() |
┬аMeasurement Range:┬а1.26 тАУ 1.70 RI; 0 тАУ 95% Brix Accuracy:0.00004 RI; 0.03 Brix Electronic Temperature Control:Flexible temperature selection between 15┬░C тАУ 100┬░C; TB option: allows 15┬░C тАУ 110┬░C with one hour boost to 120┬░C |
|
| Medical Testing and Toxicology Models | рд╡рд┐рдирд┐рд░реНрджреЗрд╢ | рд╡рд┐рд╢реЗрд╖рддрд╛рдПрдВ рдПрд╡рдВ рд▓рд╛рдн |
| Measurement Range:┬а1.33 тАУ 1.53 RI; 0 тАУ 95% Brix, 1.000 тАУ 1.0500 Urine SG Accuracy:0.0002 Urine SG; 0.00004 RI; 0.01 Brix Electronic Temperature Control:Fixed temperature selection: 20┬░C and 25┬░C |
The J-Series Refractometer is chosen by more toxicology labs than any other brand. These customers know that 0.0002 Urine SG accuracy must be validated regularly and RudolphтАЩs J57 pharmaceutical refractometer ensures that the refractive index performance and calibration requirements meet government regulations. The J57HAтАЩs standard sample volume is 500 micro liters but this can be reduced to 100 micro liters by selecting theJ57HA-SV. | |
| Measurement Range:┬а1.33 тАУ 1.53 RI; 0 тАУ 95% Brix, 1.000 тАУ 1.0500 Urine SG Accuracy:0.0002 Urine SG; 0.00004 RI; 0.01 Brix Electronic Temperature Control:Fixed temperature selection: 20┬░C and 25┬░C |
SAMSHA labs doing hundreds of toxicology samples per day prefer to┬аeliminate the human factor┬аand choose large scale automation. The┬аJ57HA-UF-SP refractometer is combined with a custom automation solution that minimizes sample use and replaces the tested sample to the testing vial. | |
| Measurement Range:┬а1.33 тАУ 1.53 RI; 0 тАУ 95% Brix, 1.000 тАУ 1.0500 Urine SG Accuracy:0.0002 Urine SG; 0.00004 RI; 0.01 Brix Electronic Temperature Control:Fixed temperature selection: 20┬░C and 25┬░C |
For large hospitals doing their own pharmaceutical compounding, ensuring that their Total Parenteral Nutrition formulas are accurate is life critical.┬аThe J57TPN is a Hospital Specific pharmaceutical refractometer and was specifically customized to meet USP<797>. Please contact the factory for the white paper on this application. | |
![]() |
рдорд╛рдк рд╕реАрдорд╛: 1.26 тАУ 1.72 рдЖрд░рдЖрдИ; 0 тАУ 100% рдмреНрд░рд┐рдХреНрд╕ рд╕рдЯреАрдХрддрд╛: 0.00002 рдЖрд░рдЖрдИ; 0.015 рдмреНрд░рд┐рдХреНрд╕ рдЗрд▓реЗрдХреНрдЯреНрд░реЙрдирд┐рдХ рддрд╛рдкрдорд╛рди рдирд┐рдпрдВрддреНрд░рдг: ┬▒0.01┬░C рдкреБрдирд░реБрддреНрдкрд╛рджрди рдХреНрд╖рдорддрд╛ рдХреЗ рд╕рд╛рде 10┬░C рд╕реЗ 100┬░C рдХреЗ рдмреАрдЪ рд▓рдЪреАрд▓рд╛ рддрд╛рдкрдорд╛рди рдЪрдпрдиред |
┬аRudolphтАЩs most capable Pharmaceutical Refractometer. Perfect for todayтАЩs highly regulated laboratories offering full 21CFR Part 11 compliance. Rudolph Research is the first manufacturer to offer┬а┬аSmart MeasureтДв a system that notifies the operator of the quality and status of the sample load, as well as the sample well status. This assists the operator in producing more accurate readings, and actually documenting that the sample was properly loaded. The J457 is available in 3 configurations J457 SC тАУ Standard Bench-top, J457 WC тАУ Wall Mount, and the J457 FC тАУ Factory Configuration. These configurations allow the measurement unit to be isolated from the display unit, thus protecting it from harsh environments and messy spills. |