Rudolph Research AnalyticalLogo
  • Início
  • Produtos
    • Medidores de densidade
      • MEDIDOR DE DENSIDADE - PORTÁTIL DDM29
      • Medidor de densidade DDM 2909
      • Medidor de densidade DDM 2910
      • Medidor de densidade DDM 2911
      • Medidor de densidade DDM 2911 PLUS
      • Opções de carregamento de amostras do medidor de densidade
    • Refratômetros
      • REFRATÔMETRO - PORTÁTIL J27
      • J47
      • J57 VT
      • J157 PLUS
      • J257
      • J357
      • J457
      • Refratômetros para lentes de contato
    • Polarímetros
      • Autopol I
      • Autopol II
      • Autopol III
      • Autopol IV
      • Autopol V
      • Autopol V PLUS
      • Autopol VI
    • Sacarímetros
      • Sacarímetros Autopol IZ e IIZ
      • Sacarímetro Autopol 589
      • Sacarímetro digital Autopol 880 e 880T
      • Sacarímetro Autopol 880 PLUS e 880T PLUS
      • Células de amostra de sacarímetro
      • Especificações do sacarímetro
    • Automação
      • Autoflex® R817
      • AutoFlex® R827
      • AutoFlex® R837
    • AlcoTest-RI®
      • Financiamento de destilarias
    • VeriLinkRx Desvio de medicamentos para hospitais
    • Octapol
      • Octapol
      • Octapol® Vermelho
      • Octapol® Preto
    • Laboratório de padrões Rudolph
  • Recursos
    • Serviço + Manutenção
    • Documentos Técnicos
    • Vídeos
    • Boletins técnicos
    • Definições
  • Qualidade - Credenciamentos
  • Depoimentos
  • Rudolph Research - Informações gerais
    • Sobre nós
    • Artigos
    • Feiras comerciais
    • Comunicados à imprensa
    • Serviço + Manutenção
    • Clientes/indústrias
  • Entre em contato conosco
    • Localizador de distribuidores
    • Serviço de contato
    • Pedido de peça/solicitação de cotação
    • Solicitar informações
    • Rudolph Brasil
    • Rudolph Alemanha
    • Rudolph Japão
    • Rudolph Turkey
    • Carreiras
    • Vagas em aberto
  • Vídeos
  • Laboratório de padrões Rudolph
  • Loja
    • Carrinho
Você está aqui: Início / Documentos Técnicos / Atende ao Capítulo 831 da USP - Requisitos de validação de temperatura para refratômetros.

Atende ao Capítulo 831 da USP - Requisitos de validação de temperatura para refratômetros.

Download a PDF of this Whitepaper

Temperature validation for refractometers is crucial to ensure temperature accuracy in pharmaceutical validation according to the latest release of USP Chapter 831.

Here’s why it’s important:

Accuracy of Refractive Index Measurements: Refractive index is a temperature sensitive property, and even small temperature variations can impact the Refractive Index measurement results. In the food industry, refractometers typically measure a single product. This allows users to minimize temperature inaccuracy by applying a temperature coefficient to the result. USP General Subchapter (831) is written to test temperature measurement control accuracy because each API, Solvent, or raw material will have it’s own unique temperature coefficient. So, applying a mathematical solution to all unique samples is impossible. Pharmaceutical labs measure many different products from solvents to syrups and correction factors will not work. The USP is aware of this phenomenon and has directed temperature measurement validation at 200C and 250C.

What has changed: Given the importance of temperature, the USP has changed the validation methodology. Before December 2023, labs treated temperature validation as implied and only needed to show no major errors from temperature. After December 2023, labs must prove traceability of refractometer temperature sensors just as required for other measurement devices.

How does Rudolph address USP 831 Temperature Validation for Refractometers used in Pharmaceutical Laboratories?

Rudolph Customers have 2 choices for Refractometer Temperature Validation.

Have Rudolph perform an annual Preventative Maintenance service that includes a full instrument validation. This will include a USP compliant temperature validation/check.

Customers may also elect to purchase a Rudolph, Refractometer Temperature validation kit. (=-$1,500 USD)

Rudolph has designed a USP 831 temperature validation kit to make it possible for users to perform temperature validation on-site. This solution suits all refractometers manufactured since 2014.

• Rudolph Refractometer instruments manufactured before 2014 can be calibrated only by Rudolph trained service technicians.

• Post 2014 and pre 2024 instruments can be calibrated by end users using the Rudolph temperature calibration package. If the instrument fails calibration, then it will probably need a Rudolph trained person to adjust it.

• Post 2024 instruments will be both calibratable and adjustable in the field by users with the temperature calibration package. (Purchased as an option)

Rudolph Research Analytical 55 Newburgh Road, Hackettstown, NJ 07840 • 973-584-1558
Fax: 973-584-5440 • Email: info@rudolphresearch.com • Internet: www.rudolphresearch.com

Arquivado em: Livros brancos Marcado com: white paper

Produtos

  • Medidores de densidade
  • Refratômetros
  • Polarímetros
  • Sacarímetros
  • Automação

Recursos

  • Localizador de distribuidores
  • Vídeos
  • Artigos
  • Documentos Técnicos
  • Boletins técnicos
  • Qualidade
  • Serviço e manutenção

Informações gerais

  • Sobre nós
  • Comunicados à imprensa
  • Clientes/indústrias

Global Distributors

Distribuidores globais

Perguntas gerais

Rudolph Research Analytical
55 Newburgh Road Hackettstown, NJ, 07840 USA

Telefone: 973-584-1558
Fax: 973-584-5440
info@rudolphresearch.com
  • Início
  • Produtos
  • Recursos
  • Qualidade - Credenciamentos
  • Depoimentos
  • Rudolph Research - Informações gerais
  • Entre em contato conosco
  • Vídeos
  • Laboratório de padrões Rudolph
  • Loja

Copyright © 2026 Rudolph Research Analytical

  • Início
  • Produtos
    • Medidores de densidade
      • MEDIDOR DE DENSIDADE - PORTÁTIL DDM29
      • Medidor de densidade DDM 2909
      • Medidor de densidade DDM 2910
      • Medidor de densidade DDM 2911
      • Medidor de densidade DDM 2911 PLUS
      • Opções de carregamento de amostras do medidor de densidade
    • Refratômetros
      • REFRATÔMETRO - PORTÁTIL J27
      • J47
      • J57 VT
      • J157 PLUS
      • J257
      • J357
      • J457
      • Refratômetros para lentes de contato
    • Polarímetros
      • Autopol I
      • Autopol II
      • Autopol III
      • Autopol IV
      • Autopol V
      • Autopol V PLUS
      • Autopol VI
    • Sacarímetros
      • Sacarímetros Autopol IZ e IIZ
      • Sacarímetro Autopol 589
      • Sacarímetro digital Autopol 880 e 880T
      • Sacarímetro Autopol 880 PLUS e 880T PLUS
      • Células de amostra de sacarímetro
      • Especificações do sacarímetro
    • Automação
      • Autoflex® R817
      • AutoFlex® R827
      • AutoFlex® R837
    • AlcoTest-RI®
      • Financiamento de destilarias
    • VeriLinkRx Desvio de medicamentos para hospitais
    • Octapol
      • Octapol
      • Octapol® Vermelho
      • Octapol® Preto
    • Laboratório de padrões Rudolph
  • Recursos
    • Serviço + Manutenção
    • Documentos Técnicos
    • Vídeos
    • Boletins técnicos
    • Definições
  • Qualidade - Credenciamentos
  • Depoimentos
  • Rudolph Research - Informações gerais
    • Sobre nós
    • Artigos
    • Feiras comerciais
    • Comunicados à imprensa
    • Serviço + Manutenção
    • Clientes/indústrias
  • Entre em contato conosco
    • Localizador de distribuidores
    • Serviço de contato
    • Pedido de peça/solicitação de cotação
    • Solicitar informações
    • Rudolph Brasil
    • Rudolph Alemanha
    • Rudolph Japão
    • Rudolph Turkey
    • Carreiras
    • Vagas em aberto
  • Vídeos
  • Laboratório de padrões Rudolph
  • Loja
    • Carrinho
  • English
  • Deutsch
  • Türkçe
  • Español
  • हिंदी