Rudolph Research AnalyticalLogo
  • Início
  • Produtos
    • Medidores de densidade
      • MEDIDOR DE DENSIDADE - PORTÁTIL DDM29
      • Medidor de densidade DDM 2909
      • Medidor de densidade DDM 2910
      • Medidor de densidade DDM 2911
      • Medidor de densidade DDM 2911 PLUS
      • Opções de carregamento de amostras do medidor de densidade
    • Refratômetros
      • REFRATÔMETRO - PORTÁTIL J27
      • J47
      • J57 VT
      • J157 PLUS
      • J257
      • J357
      • J457
      • Refratômetros para lentes de contato
    • Polarímetros
      • Autopol I
      • Autopol II
      • Autopol III
      • Autopol IV
      • Autopol V
      • Autopol V PLUS
      • Autopol VI
    • Sacarímetros
      • Sacarímetros Autopol IZ e IIZ
      • Sacarímetro Autopol 589
      • Sacarímetro digital Autopol 880 e 880T
      • Sacarímetro Autopol 880 PLUS e 880T PLUS
      • Células de amostra de sacarímetro
      • Especificações do sacarímetro
    • Automação
      • Autoflex® R817
      • AutoFlex® R827
      • AutoFlex® R837
    • AlcoTest-RI®
      • Financiamento de destilarias
    • VeriLinkRx Desvio de medicamentos para hospitais
    • Octapol
      • Octapol
      • Octapol® Vermelho
      • Octapol® Preto
    • Laboratório de padrões Rudolph
  • Recursos
    • Serviço + Manutenção
    • Documentos Técnicos
    • Vídeos
    • Boletins técnicos
    • Definições
  • Qualidade - Credenciamentos
  • Depoimentos
  • Rudolph Research - Informações gerais
    • Sobre nós
    • Artigos
    • Feiras comerciais
    • Comunicados à imprensa
    • Serviço + Manutenção
    • Clientes/indústrias
  • Entre em contato conosco
    • Localizador de distribuidores
    • Serviço de contato
    • Pedido de peça/solicitação de cotação
    • Solicitar informações
    • Rudolph Brasil
    • Rudolph Alemanha
    • Rudolph Japão
    • Rudolph Turkey
    • Carreiras
    • Vagas em aberto
  • Vídeos
  • Laboratório de padrões Rudolph
  • Loja
    • Carrinho

Definições de polarimetria

Polarimetry Fundamentals – Definition – Biots Law

Polarimetry is a sensitive, nondestructive technique for measuring the optical activity exhibited by inorganic and organic compounds. A compound is considered to be optically active if linearly polarized light is rotated when passing through it. The amount of optical rotation is determined by the molecular structure and concentration of chiral molecules in the substance. Each optically active substance has its own specific rotation as defined in Biots law:

Lei Biots
Polarimetry - Biots Law

[α] = specific rotation, T = temperature, 
λ = wavelength, α = optical rotation, 
c = concentration in g/100ml, l = optical path length in dm.

Biots Law is named after Jean-Baptiste Biot and Félix Savart, who discovered this relationship in 1820. Historically, polarimetry was performed using an instrument where the extent of optical rotation is estimated by visual matching of the intensity of split fields. For this reason, the D-line of the sodium lamp at the visible wavelength of 589nm was most often employed. Specific rotation determined at the D-line is expressed by the symbol:

Specific Rotation Symbol

Polarimetry Wavelength

or

Polarimetry Wavelength 2

and much of the data available are expressed in this form. Use of lower wavelengths, such as those available with the mercury lamp lines isolated by means of filters of maximum transmittance at approximately 578, 546, 436, 405, and 365nm in a photoelectric polarimeter, have been found to provide advantages in sensitivity with a consequent reduction in the concentration of the test compound. In general, the observed optical rotation at 436nm is about double and at 365nm about three times that at 589nm. Reduction in the concentration of the solute required for measurement may sometimes be accomplished by conversion of the substance under test to one that has a significantly higher optical rotation. Optical rotation is also affected by the solvent used for the measurement, and this is always specified.

It is now common practice to use other light sources, such as xenon or tungsten halogen, with appropriate filters, because these may offer advantages of cost, long life, and broad wavelength emission range over traditional light sources

— USP<781> Download PDF

The polarimeter must be capable of giving readings to the nearest 0.01°. The scale is usually checked by means of certified quartz plates. The linearity of the scale may be checked by means of sucrose solutions.

— EP 2.2.7 Download PDF

Polarimetric Method

The polarimetric method is a simple and accurate means for determination and investigation of structure in macro, semi-micro and micro analysis of expensive and non-duplicable samples. Polarimetry is employed in quality control, process control and research in the pharmaceutical, chemical, essential oil, flavor and food industries. It is so well established that the United States Pharmacopoeia and the Food & Drug Administration include polarimetric specifications for numerous substances.

Polarimetry – Industry Applications

Research Applications

Research applications for polarimetry are found in industry, research institutes and universities as a means of:

  • Isolating and identifying unknowns crystallized from various solvents or separated by high performance liquid chromatography (HPLC).
  • Evaluating and characterizing optically active compounds by measuring their specific rotation and comparing this value with the theoretical values found in literature.
  • Investigating kinetic reactions by measuring optical rotation as a function of time.
  • Monitoring changes in concentration of an optically active component in a reaction mixture, as in enzymatic cleavage.
  • Analyzing molecular structure by plotting optical rotatory dispersion curves over a wide range of wavelengths.
  • Distinguishing between optical isomers.

In each of these applications, the AUTOPOL Polarimeter offers up to six discrete wavelength selections to observe the effect of wavelength upon an optically active substance.

Using Polarimetry in Quality and Process Control Applications

Quality and process control applications, both in the laboratory or on-line in the factory, are found throughout the pharmaceutical, essential oil, flavor, food and chemical industries. A few examples are listed below.

Pharmaceutical Industry

Polarimetry determines product purity by measuring specific rotation and optical rotation of:

  • Amino Acids.
  • Antibiotics.
  • Dextrose.
  • Steroids.
  • Amino Sugars.
  • Cocaine.
  • Diuretics.
  • Tranquilizers.
  • Analgesics.
  • Codeine.
  • Serums.
  • Vitamins.

Polarimetry for Flavor, Fragrance, and Essential Oil Industry

Utilizes polarimetry for incoming raw materials inspection of:

  • Camphors.
  • Gums.
  • Orange oil.
  • Citric acid.
  • Lavender oil.
  • Spearmint oil.
  • Glygeric acid.
  • Lemon oil.

Polarimetry for Food Industry Applications

Polarimetry – Ensures product quality by measuring the concentration and purity of the following compounds in sugar based foods, cereals and syrups:

  • Carbohydrates.
  • Lactose.
  • Raffinose.
  • Various starches.
  • Fructose.
  • Levulose.
  • Sucrose.
  • Natural monosaccharides.
  • Glucose.
  • Maltrose.
  • Xylose.

Using Polarimetry in the Chemical Industry

Polarimetry – Analyzes optical rotation as a means of identifying and characterizing:

  • Biopolymers.
  • Natural polymers.
  • Synthetic polymers.

Additional Polarimetry Articles: Polarimeters and Polarimetry

Informações sobre o polarímetro

  • Linha de Produtos Polarimeter
  • Polarímetros recondicionados
  • Vídeos sobre polarímetros
  • Rudolph FillStation™
  • Células de amostragem do polarímetro
  • Acessórios para polarímetros
  • Veja a célula técnica e o folheto padrão 913 PDF
  • Padrões de calibração
  • Guia de Seleção de Polarímetro
  • Artigos Técnicos sobre Polarímetros
  • Definições de polarimetria
  • Depoimentos
  • Gráfico de pegada do Polarímetro Autopol
  • Entre em contato com um vendedor
  • Carrinho

Informações sobre o polarímetro

  • Linha de Produtos Polarimeter
  • Polarímetros recondicionados
  • Vídeos sobre polarímetros
  • Rudolph FillStation™
  • Células de amostragem do polarímetro
  • Acessórios para polarímetros
  • Veja a célula técnica e o folheto padrão 913 PDF
  • Padrões de calibração
  • Guia de Seleção de Polarímetro
  • Artigos Técnicos sobre Polarímetros
  • Definições de polarimetria
  • Depoimentos
  • Gráfico de pegada do Polarímetro Autopol
  • Entre em contato com um vendedor
  • Carrinho
Solicitar mais informações

Produtos

  • Medidores de densidade
  • Refratômetros
  • Polarímetros
  • Sacarímetros
  • Automação

Recursos

  • Localizador de distribuidores
  • Vídeos
  • Artigos
  • Documentos Técnicos
  • Boletins técnicos
  • Qualidade
  • Serviço e manutenção

Informações gerais

  • Sobre nós
  • Comunicados à imprensa
  • Clientes/indústrias

Global Distributors

Distribuidores globais

Perguntas gerais

Rudolph Research Analytical
55 Newburgh Road Hackettstown, NJ, 07840 USA

Telefone: 973-584-1558
Fax: 973-584-5440
info@rudolphresearch.com
  • Início
  • Produtos
  • Recursos
  • Qualidade - Credenciamentos
  • Depoimentos
  • Rudolph Research - Informações gerais
  • Entre em contato conosco
  • Vídeos
  • Laboratório de padrões Rudolph
  • Loja

Copyright © 2025 Rudolph Research Analytical

  • Início
  • Produtos
    • Medidores de densidade
      • MEDIDOR DE DENSIDADE - PORTÁTIL DDM29
      • Medidor de densidade DDM 2909
      • Medidor de densidade DDM 2910
      • Medidor de densidade DDM 2911
      • Medidor de densidade DDM 2911 PLUS
      • Opções de carregamento de amostras do medidor de densidade
      • Voltar
    • Refratômetros
      • REFRATÔMETRO - PORTÁTIL J27
      • J47
      • J57 VT
      • J157 PLUS
      • J257
      • J357
      • J457
      • Refratômetros para lentes de contato
      • Voltar
    • Polarímetros
      • Autopol I
      • Autopol II
      • Autopol III
      • Autopol IV
      • Autopol V
      • Autopol V PLUS
      • Autopol VI
      • Voltar
    • Sacarímetros
      • Sacarímetros Autopol IZ e IIZ
      • Sacarímetro Autopol 589
      • Sacarímetro digital Autopol 880 e 880T
      • Sacarímetro Autopol 880 PLUS e 880T PLUS
      • Células de amostra de sacarímetro
      • Especificações do sacarímetro
      • Voltar
    • Automação
      • Autoflex® R817
      • AutoFlex® R827
      • AutoFlex® R837
      • Voltar
    • AlcoTest-RI®
      • Financiamento de destilarias
      • Voltar
    • VeriLinkRx Desvio de medicamentos para hospitais
    • Octapol
      • Octapol
      • Octapol® Vermelho
      • Octapol® Preto
      • Voltar
    • Laboratório de padrões Rudolph
    • Voltar
  • Recursos
    • Serviço + Manutenção
    • Documentos Técnicos
    • Vídeos
    • Boletins técnicos
    • Definições
    • Voltar
  • Qualidade - Credenciamentos
  • Depoimentos
  • Rudolph Research - Informações gerais
    • Sobre nós
    • Artigos
    • Feiras comerciais
    • Comunicados à imprensa
    • Serviço + Manutenção
    • Clientes/indústrias
    • Voltar
  • Entre em contato conosco
    • Localizador de distribuidores
    • Serviço de contato
    • Pedido de peça/solicitação de cotação
    • Solicitar informações
    • Rudolph Brasil
    • Rudolph Alemanha
    • Rudolph Japão
    • Rudolph Turkey
    • Carreiras
    • Vagas em aberto
    • Voltar
  • Vídeos
  • Laboratório de padrões Rudolph
  • Loja
    • Carrinho
    • Voltar
  • English
  • Deutsch
  • Türkçe
  • Español
  • हिंदी