Rudolph Research AnalyticalLogo
  • Início
  • Produtos
    • Medidores de densidade
      • MEDIDOR DE DENSIDADE - PORTÁTIL DDM29
      • Medidor de densidade DDM 2909
      • Medidor de densidade DDM 2910
      • Medidor de densidade DDM 2911
      • Medidor de densidade DDM 2911 PLUS
      • Opções de carregamento de amostras do medidor de densidade
    • Refratômetros
      • REFRATÔMETRO - PORTÁTIL J27
      • J47
      • J57 VT
      • J157 PLUS
      • J257
      • J357
      • J457
      • Refratômetros para lentes de contato
    • Polarímetros
      • Autopol I
      • Autopol II
      • Autopol III
      • Autopol IV
      • Autopol V
      • Autopol V PLUS
      • Autopol VI
    • Sacarímetros
      • Sacarímetros Autopol IZ e IIZ
      • Sacarímetro Autopol 589
      • Sacarímetro digital Autopol 880 e 880T
      • Sacarímetro Autopol 880 PLUS e 880T PLUS
      • Células de amostra de sacarímetro
      • Especificações do sacarímetro
    • Automação
      • Autoflex® R817
      • AutoFlex® R827
      • AutoFlex® R837
    • AlcoTest-RI®
      • Financiamento de destilarias
    • VeriLinkRx Desvio de medicamentos para hospitais
    • Octapol
      • Octapol
      • Octapol® Vermelho
      • Octapol® Preto
    • Laboratório de padrões Rudolph
  • Recursos
    • Serviço + Manutenção
    • Documentos Técnicos
    • Vídeos
    • Boletins técnicos
    • Definições
  • Qualidade - Credenciamentos
  • Depoimentos
  • Rudolph Research - Informações gerais
    • Sobre nós
    • Artigos
    • Feiras comerciais
    • Comunicados à imprensa
    • Serviço + Manutenção
    • Clientes/indústrias
  • Entre em contato conosco
    • Localizador de distribuidores
    • Serviço de contato
    • Pedido de peça/solicitação de cotação
    • Solicitar informações
    • Rudolph Brasil
    • Rudolph Alemanha
    • Rudolph Japão
    • Rudolph Turkey
    • Carreiras
    • Vagas em aberto
  • Vídeos
  • Laboratório de padrões Rudolph
  • Loja
    • Carrinho
Você está aqui: Início / Documentos Técnicos / Limpeza da célula do polarímetro antes de fazer uma medição

Limpeza da célula do polarímetro antes de fazer uma medição

Cleaning a Polarimeter Sample Cell – Video Transcript

Video location: Polarimeter Sample Cell Cleaning Procedures

This video gives a brief overview of the proper method of cleaning a Rudolph polarimeter cell. This video is relevant to;

40T Temptrol polarimeter cell supplied with the Autopol IV-T, V, V plus and VI – 40T Polarimeter cell is shown
32 Cell supplied for low volume measurements in a non Temptrol polarimeter like the Autopol III – The 32 Polarimeter cell is shown.
Before starting the process suitable solvents need to be selected. Often two solvents are used, one that will remove the sample and another that will remove the first solvent. Since this cell had sucrose in it I am going to use water and acetone.  – Generally solvent 1 will become the “Blank”
After cleaning the polarimeter cell will need to be dried, in a laboratory this will often mean using clean compressed or nitrogen but for this video I am going to use canned air. Shown are – Wash bottle labeled water,  Wash bottle labeled acetone, and Canned air
Inject solvent 1 and move back and forth with the syringe
Inject solvent 2 and move back and forth with a syringe
Blow the cell dry with the air
At this point the cell should be clean and dry, ready for the next sample. I am going to look down the end to confirm – Visual – End of the cell clear to end.
Poalrimeter Sample Cells

Of course my description assumes that we are going to clean the polarimeter cell immediately after measurement however people are people and mistakes happen.  Sometimes samples precipitate in the cell, sometimes people forget to clean the cell and the sample dries on the cell wall. This section shows how to pull the cell apart if simple cleaning does not suffice
Remove the ends of the cell using an allen driver
We now have access to the inside of the cell. Under normal circumstances the fluid will enter from the inlet in the outer ring, come out over the windows and then back through the inner tube
We can pull the glasses from the ends
Now all the wetted materials can be soaked in a solvent even cleaned in an ultrasonic bath
Reassembly is the same process in reverse. Just remember that the washer goes outside the glasses.
The ends only fit one way. Remember that you are sealing a precision glass on glass fitting and finger tightness is all that is needed.
The polarimeter cell is clean and now ready to be used again.

Polarimeter Sample Cell

To view the entire line of Rudolph Research Polarimeters please visit Rudolph Research Analytical or view our Autopol line of Automatic Polarimeters

 

 

 

Baixar um PDF
deste Whitepaper

Arquivado em: Artigos técnicos Marcado com: Automático, Autopol, bancada, eletrônico, laboratório, farmacêutico, polarímetro, Célula de Polarímetro, Medição de Polarímetro, polarímetros, Rotação Específica

Produtos

  • Medidores de densidade
  • Refratômetros
  • Polarímetros
  • Sacarímetros
  • Automação

Recursos

  • Localizador de distribuidores
  • Vídeos
  • Artigos
  • Documentos Técnicos
  • Boletins técnicos
  • Qualidade
  • Serviço e manutenção

Informações gerais

  • Sobre nós
  • Comunicados à imprensa
  • Clientes/indústrias

Global Distributors

Distribuidores globais

Perguntas gerais

Rudolph Research Analytical
55 Newburgh Road Hackettstown, NJ, 07840 USA

Telefone: 973-584-1558
Fax: 973-584-5440
info@rudolphresearch.com
  • Início
  • Produtos
  • Recursos
  • Qualidade - Credenciamentos
  • Depoimentos
  • Rudolph Research - Informações gerais
  • Entre em contato conosco
  • Vídeos
  • Laboratório de padrões Rudolph
  • Loja

Copyright © 2025 Rudolph Research Analytical

  • Início
  • Produtos
    • Medidores de densidade
      • MEDIDOR DE DENSIDADE - PORTÁTIL DDM29
      • Medidor de densidade DDM 2909
      • Medidor de densidade DDM 2910
      • Medidor de densidade DDM 2911
      • Medidor de densidade DDM 2911 PLUS
      • Opções de carregamento de amostras do medidor de densidade
    • Refratômetros
      • REFRATÔMETRO - PORTÁTIL J27
      • J47
      • J57 VT
      • J157 PLUS
      • J257
      • J357
      • J457
      • Refratômetros para lentes de contato
    • Polarímetros
      • Autopol I
      • Autopol II
      • Autopol III
      • Autopol IV
      • Autopol V
      • Autopol V PLUS
      • Autopol VI
    • Sacarímetros
      • Sacarímetros Autopol IZ e IIZ
      • Sacarímetro Autopol 589
      • Sacarímetro digital Autopol 880 e 880T
      • Sacarímetro Autopol 880 PLUS e 880T PLUS
      • Células de amostra de sacarímetro
      • Especificações do sacarímetro
    • Automação
      • Autoflex® R817
      • AutoFlex® R827
      • AutoFlex® R837
    • AlcoTest-RI®
      • Financiamento de destilarias
    • VeriLinkRx Desvio de medicamentos para hospitais
    • Octapol
      • Octapol
      • Octapol® Vermelho
      • Octapol® Preto
    • Laboratório de padrões Rudolph
  • Recursos
    • Serviço + Manutenção
    • Documentos Técnicos
    • Vídeos
    • Boletins técnicos
    • Definições
  • Qualidade - Credenciamentos
  • Depoimentos
  • Rudolph Research - Informações gerais
    • Sobre nós
    • Artigos
    • Feiras comerciais
    • Comunicados à imprensa
    • Serviço + Manutenção
    • Clientes/indústrias
  • Entre em contato conosco
    • Localizador de distribuidores
    • Serviço de contato
    • Pedido de peça/solicitação de cotação
    • Solicitar informações
    • Rudolph Brasil
    • Rudolph Alemanha
    • Rudolph Japão
    • Rudolph Turkey
    • Carreiras
    • Vagas em aberto
  • Vídeos
  • Laboratório de padrões Rudolph
  • Loja
    • Carrinho
  • English
  • Deutsch
  • Türkçe
  • Español
  • हिंदी