Rudolph Research AnalyticalLogo
  • Startseite
  • Produkte
    • Dichtemessgeräte
      • DICHTEMESSGERÄT - TRAGBAR DDM29
      • Dichtemessgerät DDM 2909
      • Dichtemessgerät DDM 2910
      • Dichtemessgerät DDM 2911
      • Dichtemessgerät DDM 2911 PLUS
      • Optionen für die Beladung des Dichtemessgeräts mit Proben
    • Refraktometer
      • REFRAKTOMETER - TRAGBAR J27
      • J47
      • J57 VT
      • J157 PLUS
      • J257
      • J357
      • J457
      • Refraktometer für Kontaktlinsen
    • Polarimeter
      • Autopol I
      • Autopol II
      • Autopol III
      • Autopol IV
      • Autopol V
      • Autopol V PLUS
      • Autopol VI
    • Saccharimeter
      • Autopol IZ & IIZ Saccharimeter
      • Saccharimeter Autopol 589
      • Digitales Saccharimeter Autopol 880 & 880T
      • Saccharimeter Autopol 880 PLUS & 880T PLUS
      • Saccharimeter Probenzellen
      • Saccharimeter-Spezifikationen
    • Automatisierung
      • Autoflex® R817
      • AutoFlex® R827
      • AutoFlex® R837
    • AlcoTest-RI®
      • Brennerei-Finanzierung
    • VeriLinkRx Medikamentenumleitung im Krankenhaus
    • Octapol®.
      • Octapol®.
      • Octapol® Rot
      • Octapol® Schwarz
    • Rudolph-Normen-Labor
  • Ressourcen
    • Service + Wartung
    • Weiße Papiere
    • Videos
    • Technische Bulletins
    • Definitionen
  • Qualität - Akkreditierungen
  • Testimonials
  • Rudolph Research - Allgemeine Informationen
    • Über uns
    • Artikel
    • Messen und Ausstellungen
    • Mitteilungen an die Presse
    • Service + Wartung
    • Kunden/Industriezweige
  • Kontakt
    • Vertriebspartner-Suchmaschine
    • Kontakt Service
    • Teilbestellung/Angebotsanfrage
    • Informationen anfordern
    • Rudolph Brasilien
    • Rudolph Deutschland
    • Rudolph Japan
    • Rudolph Truthahn
    • Karriere
    • Offene Stellen
  • Videos
  • Rudolph-Normen-Labor
  • Shop
    • Wagen
Sie befinden sich hier: Startseite / Uncategorized / Refraktometer-Kalibrierung - 2-Punkt-Methode

Refraktometer-Kalibrierung - 2-Punkt-Methode

Refraktometer-Kalibrierung, 2-Punkt-Methode, Rudolph Research J157 - Video Transcript

Ressourcen für die Refraktometer-Kalibrierung - für Labor-Refraktometer-Benutzer, die ein automatisches Refraktometer von Rudolph Research verwenden.
Hallo, ich bin John Ciccarella, Service Manager für die innovativste Produktlinie von Refraktometern, die heute von Rudolph Research Analytical hergestellt wird. John Ciccarella , Rudolph Research, Service Manager mit einem J157 Refraktometer
Heute geht es um die effektive Kalibrierung Ihres Refraktometergeräts. Abgebildet: J157 Refraktometer mit den benötigten Materialien, Aceton, Wasser, Handtücher Kalibrierungstyp: 2 Punkte
Die erfolgreiche Kalibrierung eines Refraktometers lässt sich in wenigen einfachen Schritten und mit wenigen Materialien durchführen
Im Video gezeigt: Aceton, Wasser und eine zertifizierte Kalibrierungsflüssigkeit mit dem J157-Refraktometer im Hintergrund

Liste der für eine Refraktometer-Kalibrierung benötigten Materialien:

– Acetone
– Water
– Paper towels
-Certified – high calibration fluid
The refractometer is designed to guide you through the 2 point – refractometer calibration process. However, to really make sure you have effectively eliminated any potential error, it’s always good to “Zero” first. Here is how…
Step 1: Confirm the Refractometer Prism is clean and Press the zero key   Shown Screen of the J157 Refractometer.   Press Zero Button
Step 2: Now simply place Deionized Water on the prism. Verify the Prism is completely covered by the sample.  Cover the sample with the presser or with the light exclusion cap that would be supplied with a J57 model refractometer.   Press the continue key
Step 3: Once, it is noted that on the Refractometer screen that the water zero has performed successfully. The user can now clean the prism. The best way would be to use a paper towel and dry the prism thoroughly, the user can use acetone as a drying agent as needed.
Shown in Video: John cleaning the prism and also using amount of acetone.  Note: All instruments in the Rudolph Research refractometer line use Scratch resistant Sapphire Prisms making paper towel a cost effective solution to cleaning as opposed to using more expensive drying materials.
After this has been completed, I will now show you how to perform a 2 point refractometer calibration.  We will be using distilled water and an R.I. standard supplied with the Refractometer with a refractive index value of 1.42012 at 20.0c
Step 4: The way to this is by pressing a few keys on the Refractometer:
First, press the setup key and enter in the factory code of 1-2-3, Once in the main menu, press user calibration, then press two point calibration, select desired temperature in this case we will be using 20.0c, then select the desired scale and we will be using R.I. (Refractive Index), then press “Done.”  The system will now perform an air calibration.  As always, confirm the prism is very clean and covered.  This will take a few moments.
Shown in Video: Measurement bar on screen
Step 5: The refractometer will ask the user to load sample “One” on the prism dish, this simply means to add your low value fluid, and this is typically Deionized Water.  Confirm the prism is completely covered by the sample, close the presser lid and press done, and then hit continue. Shown:  John loading the water on the prism
Step 6: When the Refractometer is finished scanning the sample. User will be asked to enter the sample’s R.I. value and for Deionized Water at 20.0c this is known to be 1.33299. This can be entered into the field using the keypad on the refractometer  and then hit the enter key.
Shown in Video: The J157 Refractometer screen as value is entered. The spec value for water theoretically is 1.33299 which is factored into the calibration
Step 7: Once, the refractometer screen has accepted the water’s R.I value, the instrument will ask you to load sample 2 on the prism, the user can now clean the prism and presser again, The best way would be to use paper towel and dry the prism thoroughly, the user can use acetone as a drying agent as needed. Sample 2 will be the high R.I. refractometer calibration liquid in this case, a fluid which is certified and included when the refractometer is shipped.
Shown in Video: User pouring sample 2 on prism. Refractometer calibration fluids come with certificates and are available in a wide range of values, suited to your refractometer.
Step 8: When the refractometer is done factoring in the R.I. value of the calibration fluid it will ask the user to enter the certified value which is printed on the label of the refractometer calibration fluid bottle. In this case the fluid value is…. and this again is entered using the keypad on the J157 refractometer and then press  “Enter”
Step 9: Now the refractometer will factor in the entered value in the calibration and once a variation percentage is noted to be at 0%, you are alerted that the calibration was successful and the user can measure refractive index, assured that there will be accurate results output since the refractometer was fully calibrated.
Shown in Video: Screen of calibration completion. It is best to calibrate and achieve a 0% variation indication so all variation factors have been eliminated.
Watch this Video: Refractometer 1 and 2 Point Calibration
Additional Information is available on the Rudolph Research line of Refractometers

PDF herunterladen
dieses Whitepapers

J157 Automatisches Refraktometer

Abgelegt unter: Uncategorized, White Papers Tagged with: Kalibrieren, Kalibrierflüssigkeit, digital, Labor, R/I, Refraktometer, Refraktometer-Kalibrierung, Refraktometer

Produkte

  • Dichtemessgeräte
  • Refraktometer
  • Polarimeter
  • Saccharimeter
  • Automatisierung

Ressourcen

  • Vertriebspartner-Suchmaschine
  • Videos
  • Artikel
  • Weiße Papiere
  • Technische Bulletins
  • Qualität
  • Wartung und Instandhaltung

Allgemeine Informationen

  • Über uns
  • Mitteilungen an die Presse
  • Kunden/Industriezweige

Global Distributors

Globale Verteiler

Allgemeine Anfragen

Rudolph Forschung Analytik
55 Newburgh Road Hackettstown, NJ, 07840 USA

Telefon: 973-584-1558
Fax: 973-584-5440
info@rudolphresearch.com
  • Startseite
  • Produkte
  • Ressourcen
  • Qualität - Akkreditierungen
  • Testimonials
  • Rudolph Research - Allgemeine Informationen
  • Kontakt
  • Videos
  • Rudolph-Normen-Labor
  • Shop

Copyright © 2025 Rudolph Research Analytical

  • Startseite
  • Produkte
    • Dichtemessgeräte
      • DICHTEMESSGERÄT - TRAGBAR DDM29
      • Dichtemessgerät DDM 2909
      • Dichtemessgerät DDM 2910
      • Dichtemessgerät DDM 2911
      • Dichtemessgerät DDM 2911 PLUS
      • Optionen für die Beladung des Dichtemessgeräts mit Proben
      • Zurück
    • Refraktometer
      • REFRAKTOMETER - TRAGBAR J27
      • J47
      • J57 VT
      • J157 PLUS
      • J257
      • J357
      • J457
      • Refraktometer für Kontaktlinsen
      • Zurück
    • Polarimeter
      • Autopol I
      • Autopol II
      • Autopol III
      • Autopol IV
      • Autopol V
      • Autopol V PLUS
      • Autopol VI
      • Zurück
    • Saccharimeter
      • Autopol IZ & IIZ Saccharimeter
      • Saccharimeter Autopol 589
      • Digitales Saccharimeter Autopol 880 & 880T
      • Saccharimeter Autopol 880 PLUS & 880T PLUS
      • Saccharimeter Probenzellen
      • Saccharimeter-Spezifikationen
      • Zurück
    • Automatisierung
      • Autoflex® R817
      • AutoFlex® R827
      • AutoFlex® R837
      • Zurück
    • AlcoTest-RI®
      • Brennerei-Finanzierung
      • Zurück
    • VeriLinkRx Medikamentenumleitung im Krankenhaus
    • Octapol®.
      • Octapol®.
      • Octapol® Rot
      • Octapol® Schwarz
      • Zurück
    • Rudolph-Normen-Labor
    • Zurück
  • Ressourcen
    • Service + Wartung
    • Weiße Papiere
    • Videos
    • Technische Bulletins
    • Definitionen
    • Zurück
  • Qualität - Akkreditierungen
  • Testimonials
  • Rudolph Research - Allgemeine Informationen
    • Über uns
    • Artikel
    • Messen und Ausstellungen
    • Mitteilungen an die Presse
    • Service + Wartung
    • Kunden/Industriezweige
    • Zurück
  • Kontakt
    • Vertriebspartner-Suchmaschine
    • Kontakt Service
    • Teilbestellung/Angebotsanfrage
    • Informationen anfordern
    • Rudolph Brasilien
    • Rudolph Deutschland
    • Rudolph Japan
    • Rudolph Truthahn
    • Karriere
    • Offene Stellen
    • Zurück
  • Videos
  • Rudolph-Normen-Labor
  • Shop
    • Wagen
    • Zurück
  • English
  • Português Brasileiro
  • Türkçe
  • Español
  • हिंदी