Rudolph Research AnalyticalLogo
  • Startseite
  • Produkte
    • Dichtemessgeräte
      • DICHTEMESSGERÄT - TRAGBAR DDM29
      • Dichtemessgerät DDM 2909
      • Dichtemessgerät DDM 2910
      • Dichtemessgerät DDM 2911
      • Dichtemessgerät DDM 2911 PLUS
      • Optionen für die Beladung des Dichtemessgeräts mit Proben
    • Refraktometer
      • REFRAKTOMETER - TRAGBAR J27
      • Rudolph’s J27D Benchtop Refractometer
      • J47
      • J57 VT
      • J157 PLUS
      • J257
      • J357
      • J457
      • Refraktometer für Kontaktlinsen
    • Polarimeter
      • Autopol I
      • Autopol II
      • Autopol III
      • Autopol IV
      • Autopol V
      • Autopol V PLUS
      • Autopol VI
    • Saccharimeter
      • Autopol IZ & IIZ Saccharimeter
      • Saccharimeter Autopol 589
      • Digitales Saccharimeter Autopol 880 & 880T
      • Saccharimeter Autopol 880 PLUS & 880T PLUS
      • Saccharimeter Probenzellen
      • Saccharimeter-Spezifikationen
    • Automatisierung
      • Autoflex® R817
      • AutoFlex® R827
      • AutoFlex® R837
    • AlcoTest-RI®
      • Brennerei-Finanzierung
    • VeriLinkRx Medikamentenumleitung im Krankenhaus
    • Octapol®.
      • Octapol®.
      • Octapol® Rot
      • Octapol® Schwarz
    • Rudolph-Normen-Labor
  • Ressourcen
    • Service + Wartung
    • Weiße Papiere
    • Videos
    • Technische Bulletins
    • Definitionen
  • Qualität - Akkreditierungen
  • Testimonials
  • Rudolph Research - Allgemeine Informationen
    • Über uns
    • Artikel
    • Messen und Ausstellungen
    • Mitteilungen an die Presse
    • Service + Wartung
    • Kunden/Industriezweige
  • Kontakt
    • Vertriebspartner-Suchmaschine
    • Kontakt Service
    • Teilbestellung/Angebotsanfrage
    • Informationen anfordern
    • Rudolph Brasilien
    • Rudolph Deutschland
    • Rudolph Japan
    • Rudolph Truthahn
    • Karriere
    • Offene Stellen
  • Videos
  • Rudolph-Normen-Labor
  • Shop
    • Wagen
  • DICHTEMESSGERÄT - TRAGBAR DDM29
  • DDM 2909
  • DDM 2910
  • DDM 2911
  • DDM 2911 PLUS
  • Optionen zum Laden von Proben

Tragbares Dichtemessgerät - Handgerät - Rudolph DDM 29

Watch the video in Portuguese

Laborpräzision überall dort, wo Sie messen müssen

Unerreichte Fähigkeiten in einem vollständig tragbaren, tragbaren Dichtemessgerät

Temperaturgesteuerte Messungen bei 20° und 25°C

Das Problem der meisten tragbaren Dichtemessgeräte ist, dass sie driften, weil sie die Temperatur nicht kontrollieren. Alle Dichtemessungen sind hochgradig temperaturempfindlich, und eine mathematische Temperaturkorrektur ist für manche Anwendungen nicht gut genug. Nur eine Temperaturkontrolle führt zu der Genauigkeit, die viele Anwender benötigen. 

Das Rudolph DDM 29 Handmessgerät für die Dichte nutzt die leistungsstarke und kompakte Peltier-Technologie. Steuerung der Probentemperatur für präzises Heizen und Kühlen, um stabile und genaue Messungen bei 20 oder 25°C zu gewährleisten.

DOWNLOAD TECHNISCHES BULLETIN PDF

Robustes Edelstahl-Doppel-U-Rohr für unübertroffene Genauigkeit, Haltbarkeit und Gewichtsreduzierung

Das tragbare Dichtemessgerät DDM29 von Rudolph verwendet ein Doppel-U-Rohr aus 316er Edelstahl anstelle eines einfachen Glas-U-Rohrs. Dieses neue Design ist langlebig und korrosionsbeständig. Edelstahl wird von Kunden bevorzugt, die es leid sind, Glas-U-Rohre in anderen Handmessgeräten auszutauschen.

Das Doppel-U-Rohr-Design ermöglicht eine handgehaltene Genauigkeit und eine schnelle Messgeschwindigkeit. Es zeigt Messwerte mit 3 Dezimalstellen in 30 Sekunden und mit 4 Dezimalstellen in 60 Sekunden an.

Benutzerfreundliche GUI und helles, hintergrundbeleuchtetes Touchscreen-Display

Die extrem einfach zu bedienende grafische Benutzeroberfläche (GUI) und die Verfügbarkeit von 10 verschiedenen Sprachen auf einem hell beleuchteten 7 Zoll (128 mm) Touchscreen machen dieses Gerät zum benutzerfreundlichsten Dichtemessgerät auf dem heutigen Markt. Die Schnittstelle ist ein heller LED-Touchscreen mit einer großen, leicht zu navigierenden Benutzeroberfläche. Keine Schwierigkeiten mehr beim Ablesen von Messungen in hellen oder dunklen Umgebungen.

Bildschirm des tragbaren Dichtemessgeräts

Übertragbarkeit und Flexibilität

Lithium-Ionen-Batterien

The DDM29 gives you true portability. Powered by a fast-charging Lithium-Ion battery, it’s ready wherever you need it—receiving docks, terminals, pipelines, cargo ships, or the production floor. Each battery fully charges in about 2 hours and provides 2–4 hours of operation, depending on usage level.

For nonstop performance, the DDM29 includes a charging station and two batteries, so you can keep one in use while the other charges ensuring continuous, hassle-free operation.

Laborgenauigkeit - Überall, wo Sie messen müssen

Die meisten tragbaren Handheld-Dichtemessgeräte verwenden eine Temperaturkorrektur und geben eine Genauigkeit von 2 oder 3 Stellen an, die sehr driftanfällig ist. Das DDM29 verwendet eine Peltier-Temperaturregelung, die die Drift eliminiert und eine Genauigkeit bis auf die 4. Die Laborgenauigkeit des DDM29 verringert die Anzahl der Materialtests im Hauptlabor. Die Tests können nun im Wareneingang, im Rezepturbereich oder an anderen Stellen, an denen Messungen erforderlich sind, genau durchgeführt werden.

Das DDM29 ist mit den folgenden Methoden konform:

ASTM D7777 Standardtestmethode für Dichte, relative Dichte oder API-Gravität von flüssigem Erdöl mit einem tragbaren digitalen Dichtemessgerät

ISO 15212-1: 1998 Schwingungsmessgeräte für die Dichte. Teil 1: Laborgeräte

IP 559 Bestimmung der Dichte von Mitteldestillatbrennstoffen - Handgehaltenes Biegeschwinger-Dichtemessverfahren.

Rudolph ist ein langjähriger Teilnehmer an den ASTM Petroleum Testing, Proficiency Testing Programs. 


Tragbares Dichtemessgerät mit flexiblem Methodenmanagement

Die werksseitig installierten Messmethoden decken eine breite Palette von Branchen und Anwendungen ab. Das DDM29 ist werkseitig mit über 50 Dichte- und Konzentrationstabellen konfiguriert, z. B. Brix, %Alkohol, API und die meisten gängigen Chemikalien. Zusätzliche Tabellen, Polynome und Formeln können hinzugefügt werden.

Andere Anwendungen

  • Ätherische Öle
  • Chemikalien
  • Bier-, Würze- und Gärungsüberwachung
  • Überwachung von Rohstoffen für Erfrischungsgetränke
  • Monomere, Polymere und Elastometer
  • Pharmazeutische Rohstoffe und Fertigprodukte
  • Würze, Saft, Gärung, Spirituosen sichere Überwachung
  • Mischen, Abfüllen, Verpacken von Spirituosen und Likören
  • Schwefelsäure in Blei-Säure-Batterien
  • Klebstoffe, Leime
  • Landwirtschaft, Chemikalien und Düngemittel
  • Kolloide, Nanotechnologie
  • Tenside, Detergenzien
  • Emulsionen
  • Farben, Tinte, Toner
  • Organische und anorganische Chemikalien
  • Brennstoffzellen, Stromerzeugung, nachhaltige Kraftstoffe
  • Erfrischungsgetränke, Säfte, Tee, Kaffee
  • Erdölproben nach ASTM-, ISO- und IP-Methoden

Eine Messmethode wird genau für einzigartige Messanwendungen erstellt. Sie können Konzentrationstabellen, Formeln und Polynome verwenden, um die in Ihrem Labor oder in Ihrer Feldanwendung verwendeten Messmethoden anzupassen.

Industrieanwendungen für tragbare Dichtemessgeräte

Industrielle Anwendungen für ein tragbares Dichtemessgerät

DDM29 Density Meter Data Capacity Validation

Validated for High-Volume Measurement Data

The DDM29 Density Meter is designed to support busy laboratories, production teams, and quality control environments that generate large volumes of measurement data. To confirm reliable performance in demanding operating conditions, the DDm29 has been validated with a 50,000-record measurement dataset across core data-management functions.

Testing confirmed dependable operation across measurement storage, record retrieval, filtering, exporting, printing, and report generation. For customers who need confidence in long-term data handling, the DDM29 provides a practical, validated solution for managing high-volume measurement workflows.

Why Data Capacity Matters

In regulated and high-throughput environments, measurement data must remain accessible, organized, and reliable. As testing volume increases, users need an instrument that can do more than simply capture results. They need a system that supports efficient review, export, reporting, and record retention.

The DDM29 Density Meter helps teams maintain confidence in their data by supporting high-volume record management while preserving data completeness and output integrity.

Validated DDM29 Density Meter Data-Management Capabilities

The DDM29 Density Meter was validated using 50,000 measurement records. Key data-management functions were tested and confirmed to operate successfully, including:

  • Measurement record storage
  • Historical data retrieval
  • Record filtering
  • Data export
  • Print output
  • Report generation

This validation gives customers confidence that the DDM29 can support demanding workflows where large numbers of measurements are created, reviewed, and archived over time.

Built for Demanding Quality and Production Workflows

The DDM29 is well suited for teams that rely on frequent refractometer testing as part of daily quality checks, production monitoring, incoming material inspection, formulation review, or laboratory analysis.

By validating performance with a large measurement dataset, the DDM29 demonstrates its ability to support environments where data volume grows quickly and where historical measurement access remains important.

Reliable Export and Archiving Support

For high-volume users, routine data export and archiving are important parts of good data-management practice. The DDM29 supports practical export workflows through WiFi Share and USB options, helping users transfer records for external storage, documentation, and audit support.

These export options make it easier for teams to keep measurement records organized while supporting internal quality systems and long-term record retention practices.

FAQ’s

How many measurement records has the DDM29 Density Meter been validated with?

The DDM29 Density Meter has been validated with a 50,000-record measurement dataset across key data-management functions.

What data-management functions were validated?

Validation testing included measurement storage, historical data retrieval, filtering, export, print output, and report generation.

Does the DDM29 support exporting measurement records?

Yes. The DDM29 supports practical export workflows through WiFi Share and USB options, helping users transfer records for external storage, documentation, and archiving.

Why is data capacity important for a refractometer?

High-volume laboratories and production teams often generate thousands of measurement results over time. Validated data capacity helps ensure users can continue to access, manage, export, and report on historical measurement data efficiently.

Who benefits from high-volume refractometer data handling?

Quality control teams, production facilities, laboratories, and regulated environments benefit from reliable access to measurement history, export tools, and organized record-retention workflows.

Mehr erfahren

Contact Rudolph Research Analytical to learn how the DDM29 can support your quality-control, production, and laboratory data-management needs.

Technische Daten
DDM29 Tragbares Dichtemessgerät

GenauigkeitDichte: 0,0005 g/cm3* | Temperatur: ±0,1°C
Wiederholbarkeit
(Standardabweichung)
Dichte: 0,0001 g/cm3 Temperatur: 0.02 °C
AuflösungDichte: 0,0001 g/cm3 Temperatur: 0.01°C
Temperatur wählbar20 oder 25 °C ±0,01°C
Temperaturregelung (über Peltier gesteuert)20 oder 25°C
Temperatur in der Umgebung0 bis 40°C
%-KonzentrationsskalenÜber 30 Konzentrationsskalen
Grenzwert für die Umgebungstemperatur0 bis 40°C
Druckbereich0 bis 10 bar (145 psi )
MessmodiKontinuierlich, einzeln, mehrfach
MesstechnikMechanisch oszillierendes Doppel-U-Rohr-Verfahren
MessbereichDichte: 0-3g / cm3
Minimales ProbenvolumenEtwa 1mL
Benetzte Materialien316 Edelstahl, Teflon PTFE, ECTFE, PVDF
Unterstützte SkalenDichte, spezifisches Gewicht, Alkoholtabellen, Zucker/Extrakt, API-Funktionen, Konzentrationstabellen, Säuren, Basen, organische und anorganische Chemikalien
BetriebssystemAndroid-Betriebssystem
Messung ZeitNormalerweise 30 - 40 Sekunden nach der thermischen Äquilibrierung
AnzeigeHelle LED - 7" Touchscreen.
KommunikationsschnittstellenUSB-C, WiFi,Manual Entry, RFID, and
Barcode for entering sample IDs are all Standard
DruckenKabelloses Drucken über Airprint
FernunterstützungFehlersuche, Diagnosetools, Software
Updates über das Internet verfügbar
Interner SpeicherBis zu 6.000 Messungen
Betriebliche Abmessungen7.25" (L) x 4.75" (B) x 13.50" (H)
18.50 cm (L) x 12.25 cm (B) x 34.50 cm (H)
Versand Abmessungen18" (L) x 18" (B) x 12" (H)
Betriebsgewicht3,5 Pfund
Aufladung/Stromverbrauch
Verbrauch
Battery Longevity | 2-4 Hours depending on usage level
Im Lieferumfang des Instruments enthaltenLadestation, Spritzen, Anleitung
SchutzklasseIP54
Land der Herstellung
und Design/Garantie
1 Jahr Garantie im In- und Ausland

Informationen zum Dichtemessgerät

  • Produktlinie Dichtemessgeräte
  • Was ist ein Dichtemessgerät?
  • Optionen für die Beladung des Dichtemessgeräts mit Proben
  • Registrieren Sie Ihr Handheld-Gerät
  • Weißbücher über Dichtemessgeräte
  • Brennerei-Finanzierung
  • Instrument Fußabdruck
  • Normen für die Auftragsdichte
  • Videos zum Dichtemessgerät
  • Testimonials
  • Kontakt zu einem Vertriebsmitarbeiter
Technische Broschüre als PDF anzeigen

Produkte

  • Dichtemessgeräte
  • Refraktometer
  • Polarimeter
  • Saccharimeter
  • Automatisierung

Ressourcen

  • Vertriebspartner-Suchmaschine
  • Videos
  • Artikel
  • Weiße Papiere
  • Technische Bulletins
  • Qualität
  • Wartung und Instandhaltung

Allgemeine Informationen

  • Über uns
  • Mitteilungen an die Presse
  • Kunden/Industriezweige

Global Distributors

Globale Verteiler

Allgemeine Anfragen

Rudolph Forschung Analytik
55 Newburgh Road Hackettstown, NJ, 07840 USA

Telefon: 973-584-1558
Fax: 973-584-5440
info@rudolphresearch.com
  • Startseite
  • Produkte
  • Ressourcen
  • Qualität - Akkreditierungen
  • Testimonials
  • Rudolph Research - Allgemeine Informationen
  • Kontakt
  • Videos
  • Rudolph-Normen-Labor
  • Shop

Copyright © 2026 Rudolph Research Analytical

  • Startseite
  • Produkte
    • Dichtemessgeräte
      • DICHTEMESSGERÄT - TRAGBAR DDM29
      • Dichtemessgerät DDM 2909
      • Dichtemessgerät DDM 2910
      • Dichtemessgerät DDM 2911
      • Dichtemessgerät DDM 2911 PLUS
      • Optionen für die Beladung des Dichtemessgeräts mit Proben
    • Refraktometer
      • REFRAKTOMETER - TRAGBAR J27
      • Rudolph’s J27D Benchtop Refractometer
      • J47
      • J57 VT
      • J157 PLUS
      • J257
      • J357
      • J457
      • Refraktometer für Kontaktlinsen
    • Polarimeter
      • Autopol I
      • Autopol II
      • Autopol III
      • Autopol IV
      • Autopol V
      • Autopol V PLUS
      • Autopol VI
    • Saccharimeter
      • Autopol IZ & IIZ Saccharimeter
      • Saccharimeter Autopol 589
      • Digitales Saccharimeter Autopol 880 & 880T
      • Saccharimeter Autopol 880 PLUS & 880T PLUS
      • Saccharimeter Probenzellen
      • Saccharimeter-Spezifikationen
    • Automatisierung
      • Autoflex® R817
      • AutoFlex® R827
      • AutoFlex® R837
    • AlcoTest-RI®
      • Brennerei-Finanzierung
    • VeriLinkRx Medikamentenumleitung im Krankenhaus
    • Octapol®.
      • Octapol®.
      • Octapol® Rot
      • Octapol® Schwarz
    • Rudolph-Normen-Labor
  • Ressourcen
    • Service + Wartung
    • Weiße Papiere
    • Videos
    • Technische Bulletins
    • Definitionen
  • Qualität - Akkreditierungen
  • Testimonials
  • Rudolph Research - Allgemeine Informationen
    • Über uns
    • Artikel
    • Messen und Ausstellungen
    • Mitteilungen an die Presse
    • Service + Wartung
    • Kunden/Industriezweige
  • Kontakt
    • Vertriebspartner-Suchmaschine
    • Kontakt Service
    • Teilbestellung/Angebotsanfrage
    • Informationen anfordern
    • Rudolph Brasilien
    • Rudolph Deutschland
    • Rudolph Japan
    • Rudolph Truthahn
    • Karriere
    • Offene Stellen
  • Videos
  • Rudolph-Normen-Labor
  • Shop
    • Wagen
  • English
  • Português Brasileiro
  • Türkçe
  • Español
  • हिंदी