Rudolph Research Analytical
Logo
  • Home
  • Products
    • Density Meters
      • DENSITY METER – PORTABLE DDM29
      • Density Meter DDM 2909
      • Density Meter DDM 2910
      • Density Meter DDM 2911
      • Density Meter DDM 2911 PLUS
      • Density Meter Sample Loading Options
    • Refractometers
      • REFRACTOMETER – PORTABLE J27
      • J47
      • J57 VT
      • J157 PLUS
      • J257
      • J357
      • J457
      • Contact Lens Refractometers
    • Polarimeters
      • Autopol I
      • Autopol II
      • Autopol III
      • Autopol IV
      • Autopol V
      • Autopol V PLUS
      • Autopol VI
    • Saccharimeters
      • Autopol IZ & IIZ Saccharimeters
      • Saccharimeter Autopol 589
      • Digital Saccharimeter Autopol 880 & 880T
      • Saccharimeter Autopol 880 PLUS & 880T PLUS
      • Saccharimeter Sample Cells
      • Saccharimeter Specifications
    • Automation
      • Autoflex® R817
      • AutoFlex® R827
      • AutoFlex® R837
    • AlcoTest-RI®
      • Distillery Financing
    • VeriLinkRx Hospital Drug Diversion
    • Octapol®
      • Octapol®
      • Octapol® Red
      • Octapol® Black
    • Rudolph Standards Lab
  • Resources
    • Service + Maintenance
    • White Papers
    • Videos
    • Technical Bulletins
    • Definitions
  • Quality – Accreditations
  • Testimonials
  • Rudolph Research – General Info
    • About Us
    • Articles
    • Trade Shows
    • Press Releases
    • Service + Maintenance
    • Customers/Industries
  • Contact Us
    • Distributor Locator
    • Contact Service
    • Part Order/Quote Request
    • Request Information
    • Rudolph Brazil
    • Rudolph Germany
    • Rudolph Japan
    • Rudolph Turkey
    • Careers
  • Videos
  • Rudolph Standards Lab
  • Shop
    • Cart
You are here: Home / White Papers / Refractometer Temperature Boost Option

Refractometer Temperature Boost Option

J Series Refractometer Temperature Boost Option Technical Bulletin

J Series Refractometer with Temperature Boost Option

The Rudolph Research Analytical J Series of refractometers are able to control temperature accurately in addition to reproducibility to the range mentioned in the relevant technical bulletin. However, for certain applications beyond that range, particularly in petroleum, pharmaceutical, plastics, specialty chemical or food industries, the TB (temperature boost) option can be fitted to a standard Jx57 series refractometer as shown in the photographs below:
Refractometer Temperature boost
This option consists of different, more extensive, control elements and (in the case of the J457) extra excess heat radiation devices.

The Refractometer temperature boost – TB option has two effects:

Laboratory Refractometer – J457

  • The maximum temperature of the refractometer to be increased to 120°C for a period of 60 minutes. At the end of 60 minutes the temperature control will shut off and the instrument will cool down to ambient temperature for a period of 1 hour
  • The minimum temperature is changed from 10°C to 5°C (note that the ambient limit still applies)
    Digital Refractometer – J157, Versatile Refractometer – J257, Automatic Refractometer – J357 
  • The minimum temperature is changed from 10°C to 5°C (note that the ambient limit still applies)
  • The maximum temperature is increased to that of the model above, for example a J157WR-PLUS which normally stops at 85°C will go to 100°C (J257 temperature)

Applications requiring a refractometer temperature boost option

The Jx57 series of refractometers conform to the stringent requirements expected in a modern analytical laboratory, including the 21CFR part 11 and data integrity aspects of pharmaceutical research in addition to quality control environments. The increased temperature boost option combined with a wide RI range from 1.26 to 1.72 make the Jx57 series of refractometers the best choice for those applications which require one to measure refractive index at higher temperatures, including crude oil and petrochemical applications, a diverse array of polymers, vegetable oils, boiling confectionary and food products, flavors and extracts, as well as specialty chemicals under a wide range of conditions.

When a specific application calls for measuring RI at over 100 C, the Jx57 series of refractometers also has pertinent safety built into the system. Peltier cells control the temperature both above and below the sample prism, yet the sample cover remains cool to the touch. Depending on the prism’s configuration only a minimal volume of sample (200 μL – 1 mL) is required for an accurate measurement.

Ordering Details

The refractometer temperature boost Option can be ordered with all models of the J Series from the J157 up with the exception of flow through / pour through models.
Part Number

  • J157 TB – Use A27186
  • J157 PLUS TB – Use A27187
  • J257 TB – Use A27188
  • J357 TB – Use A27189
  • J457 TB – Use A24423

Download Refractometer
Temperature Boost Option

Filed Under: White Papers Tagged With: high temperature, refractometer, refractometers, temperature boost

Products

  • Density Meters
  • Refractometers
  • Polarimeters
  • Saccharimeters
  • Automation

Resources

  • Distributor Locator
  • Videos
  • Articles
  • White Papers
  • Technical Bulletins
  • Quality
  • Service & Maintenance

General Information

  • About Us
  • Press Releases
  • Customers/Industries

Global Distributors

Global distributors

General Inquiries

Rudolph Research Analytical
55 Newburgh Road Hackettstown, NJ, 07840 USA

Phone: 973-584-1558
Fax: 973-584-5440
info@rudolphresearch.com
  • Home
  • Products
  • Resources
  • Quality – Accreditations
  • Testimonials
  • Rudolph Research – General Info
  • Contact Us
  • Videos
  • Rudolph Standards Lab
  • Shop

Copyright © 2025 Rudolph Research Analytical

  • Home
  • Products
    • Density Meters
      • DENSITY METER – PORTABLE DDM29
      • Density Meter DDM 2909
      • Density Meter DDM 2910
      • Density Meter DDM 2911
      • Density Meter DDM 2911 PLUS
      • Density Meter Sample Loading Options
      • Back
    • Refractometers
      • REFRACTOMETER – PORTABLE J27
      • J47
      • J57 VT
      • J157 PLUS
      • J257
      • J357
      • J457
      • Contact Lens Refractometers
      • Back
    • Polarimeters
      • Autopol I
      • Autopol II
      • Autopol III
      • Autopol IV
      • Autopol V
      • Autopol V PLUS
      • Autopol VI
      • Back
    • Saccharimeters
      • Autopol IZ & IIZ Saccharimeters
      • Saccharimeter Autopol 589
      • Digital Saccharimeter Autopol 880 & 880T
      • Saccharimeter Autopol 880 PLUS & 880T PLUS
      • Saccharimeter Sample Cells
      • Saccharimeter Specifications
      • Back
    • Automation
      • Autoflex® R817
      • AutoFlex® R827
      • AutoFlex® R837
      • Back
    • AlcoTest-RI®
      • Distillery Financing
      • Back
    • VeriLinkRx Hospital Drug Diversion
    • Octapol®
      • Octapol®
      • Octapol® Red
      • Octapol® Black
      • Back
    • Rudolph Standards Lab
    • Back
  • Resources
    • Service + Maintenance
    • White Papers
    • Videos
    • Technical Bulletins
    • Definitions
    • Back
  • Quality – Accreditations
  • Testimonials
  • Rudolph Research – General Info
    • About Us
    • Articles
    • Trade Shows
    • Press Releases
    • Service + Maintenance
    • Customers/Industries
    • Back
  • Contact Us
    • Distributor Locator
    • Contact Service
    • Part Order/Quote Request
    • Request Information
    • Rudolph Brazil
    • Rudolph Germany
    • Rudolph Japan
    • Rudolph Turkey
    • Careers
    • Back
  • Videos
  • Rudolph Standards Lab
  • Shop
    • Cart
    • Back
  • Türkçe
  • Español
  • Deutsch