Rudolph Research AnalyticalLogo
  • Startseite
  • Produkte
    • Dichtemessgeräte
      • DICHTEMESSGERÄT - TRAGBAR DDM29
      • Dichtemessgerät DDM 2909
      • Dichtemessgerät DDM 2910
      • Dichtemessgerät DDM 2911
      • Dichtemessgerät DDM 2911 PLUS
      • Optionen für die Beladung des Dichtemessgeräts mit Proben
    • Refraktometer
      • REFRAKTOMETER - TRAGBAR J27
      • J47
      • J57 VT
      • J157 PLUS
      • J257
      • J357
      • J457
      • Refraktometer für Kontaktlinsen
    • Polarimeter
      • Autopol I
      • Autopol II
      • Autopol III
      • Autopol IV
      • Autopol V
      • Autopol V PLUS
      • Autopol VI
    • Saccharimeter
      • Autopol IZ & IIZ Saccharimeter
      • Saccharimeter Autopol 589
      • Digitales Saccharimeter Autopol 880 & 880T
      • Saccharimeter Autopol 880 PLUS & 880T PLUS
      • Saccharimeter Probenzellen
      • Saccharimeter-Spezifikationen
    • Automatisierung
      • Autoflex® R817
      • AutoFlex® R827
      • AutoFlex® R837
    • AlcoTest-RI®
      • Brennerei-Finanzierung
    • VeriLinkRx Medikamentenumleitung im Krankenhaus
    • Octapol®.
      • Octapol®.
      • Octapol® Rot
      • Octapol® Schwarz
    • Rudolph-Normen-Labor
  • Ressourcen
    • Service + Wartung
    • Weiße Papiere
    • Videos
    • Technische Bulletins
    • Definitionen
  • Qualität - Akkreditierungen
  • Testimonials
  • Rudolph Research - Allgemeine Informationen
    • Über uns
    • Artikel
    • Messen und Ausstellungen
    • Mitteilungen an die Presse
    • Service + Wartung
    • Kunden/Industriezweige
  • Kontakt
    • Vertriebspartner-Suchmaschine
    • Kontakt Service
    • Teilbestellung/Angebotsanfrage
    • Informationen anfordern
    • Rudolph Brasilien
    • Rudolph Deutschland
    • Rudolph Japan
    • Rudolph Truthahn
    • Karriere
    • Offene Stellen
  • Videos
  • Rudolph-Normen-Labor
  • Shop
    • Wagen

Sugar Automations Solutions

Sugar Beet and Cane Mills often need to make multiple analysis from a single sample while reducing bench chemist involvement. Automating sample loading and instrument cleaning increases throughput, increases repeatability and allows for multiple tests in a single sample.

Rudolph Research Analytical knows that Sugar Technologists around the world demand 24 hour operation, 7 days a week. Regardless of the accuracy and budget demands, Rudolph Research has a solution. The reason we understand the sugar industry’s demands and requirements is because Rudolph has been serving the industry since 1940. Throughout those 75 plus years of service, Rudolph has dedicated itself to manufacturing quality instrumentation and providing superior technical and service support, both directly and through its worldwide dealer’s network. This dedication is demonstrated by Rudolph’s installed base of over 8,000 instruments worldwide, with many of those instruments still in operation after 30 years of service. 

Gründe für die Wahl von Rudolph

• Using a Rudolph AutoFlex® R817 Automation solution in the sugar laboratory minimizes sample
handling and measures: Brix, Purity, Density, SG, and pH in 2 minutes and with just 8ml of sample.

• Rudolph automation systems clean automatically with up to 3 choices of solvent

Typical Rudolph AutoFlex® Customers

Minn-Dak Farmers Cooperative and Amalgamated Sugar use a Rudolph AutoFlex® with a 5 instrument package to handle their high sample throughput and multi parameter testing. 


Tate and Lyle use Rudolph Automation and Refractometer, Polarimeter, Density Meter and a Colorimeter to perform QC measurements for High Fructose Corn Syrup

Streamline your sugar testing needs

Standard Features

• 3 rinses available

• Inside and Outside Needle Wash

• Low Solvent Level Detection

• Suction Mode

• Pressure Gas Displacement Mode

• Flexible Method Selection 

• LIMS Compatible

• 5 Test Tube Racks Handling 50 Samples

• Rack Specific Method Selection

• SAP Compatible

• Variable Drying and Rinse Times

Optional Features

• Racks (customized to your bottles)

• Heated Racks

• Built in Bar Code / Label Reader with Vial Spinner

• Handheld Bar Code / Label Reader

• Automated Empty Vial Recognition

• Extra Racks

• Sample Return Feature: Allows 95% of sample
    to be returned to sample vial 

• Custom Programming

Specifications:

Sample Viscosity:
Samples up to 36,000 mPa-s (cP)

Sample Volume Requirements:
3.5ml typical, optional to 1.5ml or 1.5mL to 10mL config. dependent

Rack Sample Capacity:
50 – 16 x 100mm test tubes. 70 – 13 x 100 mm, or optionally dozens of sample vial configurations and capacities.

Cleaning Cycle:
1:45 minutes nominal – time varies by application

Full Measurement and Cleaning Cycle:
2:30 minutes nominal – time varies by application

Software Interface:
Compatible with Rudolph Research instruments
running Windows Embedded OS

Power Requirements:
100-240 volts – 50-60 Hz – 10 amps

Operating Dimensions: 
L: 24”          W: 24”        H: 20.5”
L: 61 cm      W: 61 cm   H: 52cm

Weight:  42 lbs. / 19 kg

Produkte

  • Dichtemessgeräte
  • Refraktometer
  • Polarimeter
  • Saccharimeter
  • Automatisierung

Ressourcen

  • Vertriebspartner-Suchmaschine
  • Videos
  • Artikel
  • Weiße Papiere
  • Technische Bulletins
  • Qualität
  • Wartung und Instandhaltung

Allgemeine Informationen

  • Über uns
  • Mitteilungen an die Presse
  • Kunden/Industriezweige

Global Distributors

Globale Verteiler

Allgemeine Anfragen

Rudolph Forschung Analytik
55 Newburgh Road Hackettstown, NJ, 07840 USA

Telefon: 973-584-1558
Fax: 973-584-5440
info@rudolphresearch.com
  • Startseite
  • Produkte
  • Ressourcen
  • Qualität - Akkreditierungen
  • Testimonials
  • Rudolph Research - Allgemeine Informationen
  • Kontakt
  • Videos
  • Rudolph-Normen-Labor
  • Shop

Copyright © 2026 Rudolph Research Analytical

  • Startseite
  • Produkte
    • Dichtemessgeräte
      • DICHTEMESSGERÄT - TRAGBAR DDM29
      • Dichtemessgerät DDM 2909
      • Dichtemessgerät DDM 2910
      • Dichtemessgerät DDM 2911
      • Dichtemessgerät DDM 2911 PLUS
      • Optionen für die Beladung des Dichtemessgeräts mit Proben
    • Refraktometer
      • REFRAKTOMETER - TRAGBAR J27
      • J47
      • J57 VT
      • J157 PLUS
      • J257
      • J357
      • J457
      • Refraktometer für Kontaktlinsen
    • Polarimeter
      • Autopol I
      • Autopol II
      • Autopol III
      • Autopol IV
      • Autopol V
      • Autopol V PLUS
      • Autopol VI
    • Saccharimeter
      • Autopol IZ & IIZ Saccharimeter
      • Saccharimeter Autopol 589
      • Digitales Saccharimeter Autopol 880 & 880T
      • Saccharimeter Autopol 880 PLUS & 880T PLUS
      • Saccharimeter Probenzellen
      • Saccharimeter-Spezifikationen
    • Automatisierung
      • Autoflex® R817
      • AutoFlex® R827
      • AutoFlex® R837
    • AlcoTest-RI®
      • Brennerei-Finanzierung
    • VeriLinkRx Medikamentenumleitung im Krankenhaus
    • Octapol®.
      • Octapol®.
      • Octapol® Rot
      • Octapol® Schwarz
    • Rudolph-Normen-Labor
  • Ressourcen
    • Service + Wartung
    • Weiße Papiere
    • Videos
    • Technische Bulletins
    • Definitionen
  • Qualität - Akkreditierungen
  • Testimonials
  • Rudolph Research - Allgemeine Informationen
    • Über uns
    • Artikel
    • Messen und Ausstellungen
    • Mitteilungen an die Presse
    • Service + Wartung
    • Kunden/Industriezweige
  • Kontakt
    • Vertriebspartner-Suchmaschine
    • Kontakt Service
    • Teilbestellung/Angebotsanfrage
    • Informationen anfordern
    • Rudolph Brasilien
    • Rudolph Deutschland
    • Rudolph Japan
    • Rudolph Truthahn
    • Karriere
    • Offene Stellen
  • Videos
  • Rudolph-Normen-Labor
  • Shop
    • Wagen
  • English
  • Português Brasileiro
  • Türkçe
  • Español
  • हिंदी