Polarimeters From Rudolph Research Analytical
Polarimeters from Rudolph Research for chemical, sugar, pharmaceutical, cosmetics, essential oils, education, and university laboratories. Additionally, view each Polarimeter instrument below.
VER UN VIDEO SOBRE LA LINEA DE POLARIMETROS RUDOLPH AUTOPOL
¿Problemas para ver este video? Haga clic aquí
AUTOPOL VI – Laboratory Polarimeter
The AUTOPOL VI Automatic Polarimeter is Rudolph’s top of the line six wavelength polarimeter. Its specifically designed for the most demanding analytical laboratories. In addition, the built in Ethernet port allows saving data directly to your network server. It also allows printing to a network printer. For instance, The USB ports allow printing to a printer that has Windows® drivers. This unit comes standard with six wavelengths. It also comes with TempTrol™ NIST estándar trazable, célula de muestra TempTrol™, célula de validación de temperatura TempTrol™ y documentación IQOQ (Calidad de Instalación, Calidad de Operación). Polarímetro AUTOPOL VI.
- 0.0003 accuracy for low rotation samples of ±1° Arc.
- Ethernet port for network connection.
- Save measurements direct to your network as well as server.
- 3 USB ports.
- Connect to Windows® based printer via USB.
- 21CFR Parte 11 Compliant.
- TempTrol™ Electronic Heating as well as Cooling.
- Additionally, Six Standard Wavelengths.
- Most importantly, designed for demanding analytical laboratories.
AUTOPOL V PLUS – Pharmaceutical Polarimeter
The AUTOPOL V PLUS Automatic Polarimeter is Rudolph’s top of the line six wavelength instrument. Its specifically designed with the input of the world’s largest pharmaceutical companies. This unit comes standard with 21CFR11 software. It also comes with Rudolph’s Patented TempTrol™ System. Therefore, it electronically heats and cools the sample to a specified temperature without the use of water circulation. This unit includes all wavelengths necessary to measure 99% of all monographs found in the USP, EP, JP and BP. In addition, IQOQ (Installation Quality Operation Quality) documentation is included with the instrument.
- 6m de resistencia al ácido HCl: Recubrimiento de acero Silco en la superficie de transferencia de temperatura de la cámara y una célula de medición de Hastelloy con NIST certificado que certifica la longitud del camino óptico.
- Viene con una placa de cuarzo rastreable por el NIST con tres rotaciones: Arco de +0,998°, Arco de +10,998°, Arco de -10.000°. Cada rotación tiene un NIST certificado.
- Intuitive Windows® based navigation architecture.
- 3 USB ports.
- Connect to Windows® based printer via USB.
- Ethernet port for network cable connection.
- Internet access allowing connection to Rudolph’s service department for remote testing and diagnostics.
- Save measurement data to your network/server.
- TempTrol™ Electronic Heating and Cooling.
- Six Standard Wavelengths.
AUTOPOL V – Digital Polarimeter
El Polarímetro Automático AUTOPOL V está diseñado para los actuales laboratorios analíticos regulados por la FDA. Tanto si es un laboratorio farmacéutico, nutracéutico o universitario, el AUTOPOL V tiene las características estándar de medición y cumplimiento que debe tener, incluyendo:
- 21CFR Parte 11 Compliant.
- Temptrol™ Electronic Heating and Cooling.
- Six standard wavelengths.
- Touch panel user interface.
- Designed for use in FDA regulated Pharmaceutical, Nutraceutical and cGMP/GLP laboratories.
AUTOPOL IV – Essential Oils Polarimeter
The AUTOPOL IV Automatic Polarimeter is available in one, two and six wavelength versions. It has a more expensive optical system than the Autopol III. It is the system of choice for research universities, pharmaceutical and fine chemical research departments. This instrument is also excellent for studying racemics and kinetics. Temperature control is done using the patented Rudolph TempTrol™ system. IQOQ documentation is included with the instrument.
- Medidas Rotación óptica, Rotación específica, Concentration, and User Defined Scales.
- Temptrol™ Electronic Heating and Cooling.
- 1, 2 and 6 wavelength models.
- Temperature Correction.
- Real-time clock.
- Print-out format control.
- Designed for use in Pharmaceutical, University, Essential Oil as well as related industries.
AUTOPOL III – Automatic Polarimeter
The AUTOPOL III Automatic Polarimeter is Rudolph’s two wavelength pharmaceutical and research grade instrument. To clarify, it has a ±0.002 Degrees Rotación óptica precisión para rotaciones de hasta 1° de arco. Este polarímetro viene de serie con dos longitudes de onda: 589 nm y 546 nm y pasará una FDA inspection with the appropriate water bath to control temperature or with optional Temptrol™ Electronic Heating and Cooling. IQOQ documentation is included with the instrument.
- Medidas Rotación óptica, Rotación específica, Concentration, and °Z (ISS) Sugar Degrees.
- Resolución: 0.001° Arco Optical Rotation.
- Accuracy: 0.002° Arc up to 1° as well as 0.2% above 1°.
- Simple touch panel user interface.
- Built in temperature probe.
- Temptrol™ Electronic Heating and Cooling is available as an option.
- 8 inch Color Display as well as 800 x 600 pixel resolution with 400 nits of brightness.
- Data storage – 32 GB Non-removable Compact Flash.
- Optional Wavelengths 365nm, 405nm, 436nm, 578nm.
- 3- USB Ports, 2- RS232 serial ports. In addition, Ethernet Port for Network Communication.
- A Dual wavelength Pharmaceutical as well as Research grade instrument.
Choosing an Instrument for Pharmaceutical Laboratories
Below is an example of why Polarimeters with accuracy of ±0.02 and ±0.01 accuracy polarimeters are not suitable for pharmaceutical applications. Please review the USP monograph for the material Ofloxacin. In addition, Ofloxacin must have a specific rotation between +1° and -1° at a concentration of 10mg per ml. Biots Law:
The Autopol I has an accuracy of ±0.02° optical rotation. For example, below is how its relative accuracy affects a hypothetical Ofloxacin sample:
You cannot successfully inspect a pharmaceutical (such as Ofloxacin) having a Specific Rotation between+1 and ±1 and a 1% concentration, which is quite common for most pharmaceuticals, with a polarimeter instrument that has an accuracy of ±2.0 in Specific Rotation.
In addition, the Autopol IV has an accuracy of 0.002 for Optical Rotations of 1°Arc for a total unknown of +/-0.002 under the same conditions:
AUTOPOL II – Education Polarimeter
El Polarímetro Automático AUTOPOL II es un polarímetro de propósito general con ±0,01 Grados Rotación óptica precisión. Esta precisión es aplicable a la alimentación, la educación universitaria, muchas aplicaciones químicas, de sabores y fragancias, así como a la inspección farmacéutica en algunos países.
- Medidas Rotación óptica, Rotación específica, Concentration, as well as °Z (ISS) Sugar Degrees.
- Resolución: 0.01° Arco Optical Rotation.
- Precisión: 0.01° de arco Rotación óptica as well as 0.003°Z (ISS) Sugar Degrees.
- Simple touch panel user interface.
- Built in temperature probe.
- Temptrol™ Electronic Heating and Cooling is available as an option.
- 8 inch Color Display, 800 x 600 pixel resolution as well as 400 nits of brightness.
- Data storage as well as 32 GB Non-removable Compact Flash.
- Optional Wavelengths 365nm, 405nm, 436nm, 578nm, 633nm.
- 3- USB Ports, 2- RS232 serial ports. In addition, Ethernet Port for Network Communication.
- Designed as a general purpose dual wavelength Automatic Polarimeter for budget focused Contract Laboratories, Food Laboratories as well as College Chemistry Laboratories.
AUTOPOL I – Sugar Polarimeter
The AUTOPOL I Automatic Polarimeter instrument is Rudolph’s single wave length model with an accuracy of ±0.02 Degrees Optical Rotation. This accuracy is fine for food and educational applications where budget is critical but state of the art quality is still important.
- Medidas Rotación óptica, Rotación específica, Concentration, as well as °Z (ISS) Sugar Degrees.
- Resolution: 0.01° Arc Optical Rotation.
- Accuracy: 0.02° Arc Optical Rotation as well as 0.03°Z (ISS) Sugar Degrees.
- Simple touch panel user interface.
- Built in temperature probe.
- Temptrol™ Electronic Heating as well as Cooling is available as an option.
- 8 inch Color Display, 800 x 600 pixel resolution as well as 400 nits of brightness.
- Data storage as well as 32 GB Non-removable Compact Flash.
- Built in temperature probe.
- 3 USB Ports, 2 RS232 serial ports. In addition Ethernet Port for Network Connection.
- Designed as a single wavelength instrument for Food, Education, certain Pharmaceutical applications. It is also used for less demanding applications where budget is critical, but quality is still important.
Looking to automate sample measurements – Automatización del laboratorio
Used Polarimeters – Factory Refurbished Polarimeters
- High Quality polarimeters as well as a lower cost.
- Factory rebuilt and re-calibrated.
- 2 year warranties.
- Great for low volume labs, Universities, and above all, where cost is a critical factor.
Todos los instrumentos de Rudolph llevan nuestro exclusivo compromiso de servicio a su instrumento.
Rudolph Research Analytical offers a comprehensive range of Preventive Maintenance and Service Programs. Additionally, Rudolph has demonstrated a commitment to its customers. We do this by keeping installed instruments operational. We do this not only for 20 years, but in some cases for over 40 years. In other words, this long-term commitment to keeping our instruments running makes the cost of ownership, over the life of a Rudolph Polarimeter Instrument, one of the lowest in the laboratory market segment. At the date this document was published, there is no other laboratory instrument manufacturer guaranteeing service and technical support for 20 years. Vea los 20 servicios garantizados.