Rudolph Forschung AnalytischesLogo
  • Startseite
  • Produkte
    • Dichte-Messgeräte
      • Dichtemesser DDM 2909
      • Dichtemesser DDM 2910
      • Dichtemesser DDM 2911
      • Dichtemesser DDM 2911 PLUS
      • Density Meter Sample Loading Options
    • Refraktometer
      • J47
      • J57 VT
      • J157 PLUS
      • J257
      • J357
      • J457
      • Contact Lens Refractometers
    • Polarimeter
      • Autopol I
      • Autopol II
      • Autopol III
      • Autopol IV
      • Autopol V
      • Autopol V PLUS
      • Autopol VI
    • Zucker-Messgeräte
      • Saccharimeter Autopol 589
      • Digital Saccharimeter Autopol 880 & 880T
      • Saccharimeter Autopol 880 PLUS & 880T PLUS
      • Saccharimeter-Probenzellen
      • Saccharimeter-Spezifikationen
    • Automatisierung
      • AutoFlex® R817
      • AutoFlex® R827
      • AutoFlex® R837
    • AlcoTest-RI®
      • Distillery Financing
    • VeriLinkRx Hospital Drug Diversion
    • Octapol®
      • Octapol®
      • Octapol® Red
      • Octapol® Black
    • Rudolph Standards Lab
  • Ressourcen
    • Service + Wartung
    • Whitepaper
    • Technische Mitteilungen
    • Definitionen
  • Qualität - Akkreditierungen
  • Empfehlungsschreiben
  • Rudolph Research – General Info
    • Über uns
    • Artikel
    • Messen
    • Pressemitteilungen
    • Service + Wartung
    • Kunden/Branchen
  • Kontakt
    • Verteiler-Lokalisator
    • Kontakt Dienst
    • Informationen anfordern
    • Careers
      • Jobs
  • Videos
    • Anfahrtsbeschreibung
    • Video-Broschüren
  • Rudolph Standards Lab
  • Laden
    • Cart
  • J47
  • J57 VT
  • J157 Plus
  • J257
  • J357
  • J457
  • Contact Lens Refractometers

Refractometer J257

Versatile Refractometer – J257 with Extended Measurement Range

A highly versatile Refractometer, the Rudolph Research J257 was developed by working together with laboratory refractometer users from the polymer, Erdöl,  Petrochemie, pharmazeutische und ätherisches Öl industries. The J257 is a fully Automatic, Digital Refractometer, featuring electronic cooling and heating. In addition it has an extended Refractive Index (RI) measurement range. The J257 is part of the Rudolph Research Rudolph Research Refraktometer Produktlinie.

Video mit dem Weitbereichsrefraktometer J257 von Rudolph Research ansehen


Probleme bei der Anzeige dieses Videos? Klicken Sie hier

Versatile Refractometer for a Wide Range of Applications

Rudolph Research’s J257 is designed as a multipurpose versatile refractometer for a broad range of (RI) refractive index measurement applications.  Many laboratories need the versatility of a wide range refractometer as they measure many varied samples. The J257 measures the widest possible range of Refractive Index from 1.26 to 1.72 RI. This means that this instrument can measure many materials that a refractometer with only a food refractive index range of 1.33-1.53 cannot.

Automatic Refractometer Operation

Die Bedienung des Rudolph J257 ist so einfach wie das Auflegen einer Probe auf das Prisma, das Schließen des Deckels und das Ablesen der Ergebnisse auf dem digitalen Bildschirm - alles in nur wenigen Sekunden. Da das Gerät vollautomatisch arbeitet, gibt es keine Schattenlinien, die übereinstimmen müssen, und es gibt kein Okular, das vom Bediener bestimmt oder manuell eingestellt werden muss. Wenn der Modus "Messen, wenn stabil" gewählt ist, wartet der J257 automatisch, bis die Probe auf eine vordefinierte Temperatur erwärmt oder abgekühlt ist, bevor er eine Messung einleitet.

Versatile Refractometer With An Easy To Read LCD Interface

Ein großes 7,5 cm x 10 cm großes, hintergrundbeleuchtetes, digitales LCD-Display mit Kaltkathodenfluoreszenz ermöglicht die einfache Anzeige von Skala, Probentemperatur, eingestellter Temperatur, Lufttemperatur, Uhrzeit, Datum und Temperaturkorrekturstatus. Alle Funktionen werden über ein Touchscreen-Panel aktiviert, das nicht wie herkömmliche oder abnehmbare Tastaturen verschleißen oder verlegt werden kann. Der robuste Touchscreen ist resistent gegen Fingernägel, scharfe Gegenstände, Chemikalien und Säuren.

Versatile Refractometer Data Storage Options

Das J257-Refraktometer bietet verschiedene Datenspeicheroptionen, um den Anforderungen jedes Labors und jeder Compliance-Anforderung gerecht zu werden. Mit 32 MB On-Board-Speicher kann das J257 als Standalone-Gerät betrieben werden, oder es können Memory Sticks verwendet werden, um den Speicher zu erweitern oder Daten leicht auf einen PC zu transportieren. Der J257 lässt sich einfach an Ihr Netzwerk anschließen oder kann mit einem PC verbunden werden. Für alle Datenspeicheroptionen siehe: Refraktometer-Datenspeicherung

A Versatile Refractometer with Dual Temperature Control System

Im Gegensatz zu anderen temperaturgesteuerten Refraktometern verfügt das digitale Refraktometer J257 über eine Temperatursteuerung sowohl von oberhalb als auch von unterhalb der Probe. Die Probenabdeckung wird auf die gleiche Temperatur wie das Prisma geregelt und ist, wenn sie abgesenkt wird, so ausgelegt, dass eine temperaturgesteuerte Mikroumgebung entsteht, die eine unübertroffene Temperaturstabilität, schnelle Messzeit und minimale Verdunstung bietet. Je nach Optionen kann die Probenabdeckung auch zur Einleitung der Messung verwendet werden. Das bedeutet, dass der Bediener den Refraktometer-Bildschirm täglich nicht einmal berühren muss, sondern einfach nur die Abdeckung herunterklappen und die Messung startet automatisch.
Versatile Refractometer - Wide Range Sample Cover

Optionale Probenpresse

The J257 is available with an optional Temperature Controlled Sample Presser that touches the sample. This make the J257 one of the most versatile refractometers for a very wide range of uses. Compared with the standard temperature controlled Cover, the optional Presser reduces the empty volume of the measurement area thereby decreasing evaporation and at the same time helping to evenly spread semi-solid materials over the refractometer’s measurement prism. This feature offers improved refractive index (RI) readings on a wide range of often hard to measure samples.
Versatile Refractometer with Sample Well Cover

More about Rudolph Refractometer Sample Cover Options

J257 Versatile Refractometer offers full and Traceable Calibration

Rudolph Standards Lab

The Rudolph J257 Versatile Refractometer offers 1 pt, 2 pt, or a full multi-point calibration. Calibration can be done at 20°C, 25°C or any user selectable temperature within the available range. Regardless of how many times the refractometer has been calibrated, it can always be restored to the initial factory calibration if required.

Vom Benutzer konfigurierbar

Versatile refractometers in the lab have the advantage of being able to display a lot of information, however this versatility can also lead to confusion, with extra buttons and by forcing the operator to interpret extra information that may have no relevance to their application. The J Series customizable digital refractometer, display allows the instrument to be configured to exactly what is required for each application. The customizable keypad can be “locked out” or just a few keys can be operable, i.e. the measure key, print key, zero key, customer specified sample keys or any combination thereof. The lockout function, calibration and other functions are all password protected.

Versatile Refractometer Sample CoverVersatile Refractometer Sample Well East To Clean

 

Very Durable – Rugged

Die Rudolph J-Serie Refraktometer are rugged, laboratory instruments offering a sapphire prism for high mechanical and chemical durability. The sample well is made of acid resistant ,316 stainless steel with a Techtron sealing ring. There is no lamp to change, the LED light source is guaranteed for 1,000,000 measurements.

Refraktometer-Optionen und Zubehör

  • NIST rückführbare Kalibrierflüssigkeiten
  • IQ/OQ/PQ-Paket
  • Säurebeständige Probenvertiefung und -platte
  • Drucker
  • Vorprogrammierte benutzerdefinierte Skala
  • Software zur Datenerfassung
  • Kleines Volumen, leicht zu reinigende Probenvertiefung
  • Verschiedene Messwellenlängen
  • Strichcode-Lesegerät

Zurück zur Ansicht der gesamten Rudolph-Forschung Refraktometer Produktlinie
20-Jahresfahne

Alle Rudolph-Instrumente tragen unsere exklusive 20-Verpflichtung, Ihr Instrument zu warten.

Rudolph Research Analytical bietet ein umfassendes Angebot an Programmen für vorbeugende Wartung und Service. Rudolph hat sein Engagement für seine Kunden bewiesen, indem es installierte Instrumente nicht nur seit 20 Jahren, sondern in einigen Fällen seit über 40 Jahren in Betrieb hält. Diese langfristige Verpflichtung, unsere Instrumente in Betrieb zu halten, macht die Betriebskosten über die gesamte Lebensdauer eines Rudolph Instruments zu einem der niedrigsten im Labormarktsegment. Zum Zeitpunkt der Veröffentlichung dieses Dokuments gibt es keinen anderen Hersteller von Laborgeräten, der Service und technische Unterstützung für 20 Jahre garantiert. Sehen Sie sich die gesamte 20-Service-Garantie an. 

J257 Digitale Refraktometer-Spezifikationen
Mess-Skalen Brechungsindex (RI) BRIX (% Saccharose) Temperaturkorrigierte BRIX Temperaturkorrigierte RI 100 Benutzerprogrammierbare Skalen
Messbereich 1,26 - 1,72 RI, 0 - 100 BRIX
Entschließung Refractive index 0.0001(Standard), 0.00001 (Optional) BRIX 0.1(Standard), 0.01 (Optional)
Wiederholbarkeit ±0,0001 RI, ±0,1 BRIX
Genauigkeit ±0,0001 RI, ±0,1 BRIX
Optische Wellenlänge 589,3 nm (andere Wellenlängen verfügbar)
Prisma Industrieller Saphir
Lichtquelle Licht Emittierende Diode (Lebensdauer: >100.000 Std.)
Reaktionszeit Kontinuierliche Auslesung oder benutzerprogrammierbare Verzögerung (d.h. eine 25ºC-Probe kann auf 20ºC gekühlt und in 20 Sekunden gemessen werden)
Kommunikationsschnittstelle 3 USB RS232-Schnittstellen Cat5-Netzwerk (Ethernet)
Analoge Steuerung 0-10 Volt, 4-20 mA
Temp. Regelbereich (innerhalb 10C der Umgebung) 10ºC - 100ºC *andere Temperaturregelungsoptionen sind verfügbar - 5ºC - 110ºC mit Temperaturerhöhungsoption verfügbar.
Temp. Sensor-Genauigkeit ±0,05ºC
Umgebungstemp. Begrenzung 5ºC - 40ºC
Temp. Korrekturbereich 4ºC - 95ºC (für reine Saccharoselösungen)
Temp. Steuerung Prismenoberfläche und Drücker
Kalibrierung 1, 2 oder vollständige Mehrpunkt-Kalibrierung
Betriebs-Abmessungen L: 15,25" W: 10" H: 4,5" / 23 lbs.
Versand-Abmessungen L: 26" W: 21" H: 16 / 30 Pfund.
Leistungsbedarf 100-240 Volt, 50 Hz - 60 Hz

Refraktometer-Informationen

  • Refraktometer-Produktlinie
  • Refraktometer-Auswahlhilfe
  • Measuring Refractive Index – Refractometry
  • Refraktometer-Videos
  • Refraktometer-Kalibrierungsstandards
  • Empfehlungsschreiben
  • Refractometer Sample Cover Options
  • Refraktometer-Zubehör
  • VeriLinkRX Demonstration Request Form
  • Kontakt zu einem Verkäufer

Produktspezifikationen anzeigen

View Technical Brochure PDF

Produkte

  • Dichte-Messgeräte
  • Refraktometer
  • Polarimeter
  • Zucker-Messgeräte
  • Automatisierung

Ressourcen

  • Verteiler-Lokalisator
  • Videos
  • Artikel
  • Whitepaper
  • Technische Mitteilungen
  • Qualität
  • Service und Wartung

Allgemeine Informationen

  • Über uns
  • Messen
  • Pressemitteilungen
  • Kunden/Branchen
  • Sitemap

Globale Vertriebspartner

Globale Vertriebspartner

Allgemeine Anfragen

Rudolph Forschung Analytisch
55 Newburgh Road Hackettstown, NJ, 07840 USA

Telefon: 973-584-1558
Fax: 973-584-5440
info@rudolphresearch.com
  • Startseite
  • Produkte
  • Ressourcen
  • Qualität - Akkreditierungen
  • Empfehlungsschreiben
  • Rudolph Research – General Info
  • Kontakt
  • Videos
  • Rudolph Standards Lab
  • Laden

Copyright © 2023 Rudolph Research Analytical

  • Startseite
  • Produkte
    • Dichte-Messgeräte
      • Dichtemesser DDM 2909
      • Dichtemesser DDM 2910
      • Dichtemesser DDM 2911
      • Dichtemesser DDM 2911 PLUS
      • Density Meter Sample Loading Options
      • <i class="fa fa-chevron-left"></i> Back
    • Refraktometer
      • J47
      • J57 VT
      • J157 PLUS
      • J257
      • J357
      • J457
      • Contact Lens Refractometers
      • <i class="fa fa-chevron-left"></i> Back
    • Polarimeter
      • Autopol I
      • Autopol II
      • Autopol III
      • Autopol IV
      • Autopol V
      • Autopol V PLUS
      • Autopol VI
      • <i class="fa fa-chevron-left"></i> Back
    • Zucker-Messgeräte
      • Saccharimeter Autopol 589
      • Digital Saccharimeter Autopol 880 & 880T
      • Saccharimeter Autopol 880 PLUS & 880T PLUS
      • Saccharimeter-Probenzellen
      • Saccharimeter-Spezifikationen
      • <i class="fa fa-chevron-left"></i> Back
    • Automatisierung
      • AutoFlex® R817
      • AutoFlex® R827
      • AutoFlex® R837
      • <i class="fa fa-chevron-left"></i> Back
    • AlcoTest-RI®
      • Distillery Financing
      • <i class="fa fa-chevron-left"></i> Back
    • VeriLinkRx Hospital Drug Diversion
    • Octapol®
      • Octapol®
      • Octapol® Red
      • Octapol® Black
      • <i class="fa fa-chevron-left"></i> Back
    • Rudolph Standards Lab
    • <i class="fa fa-chevron-left"></i> Back
  • Ressourcen
    • Service + Wartung
    • Whitepaper
    • Technische Mitteilungen
    • Definitionen
    • <i class="fa fa-chevron-left"></i> Back
  • Qualität - Akkreditierungen
  • Empfehlungsschreiben
  • Rudolph Research – General Info
    • Über uns
    • Artikel
    • Messen
    • Pressemitteilungen
    • Service + Wartung
    • Kunden/Branchen
    • <i class="fa fa-chevron-left"></i> Back
  • Kontakt
    • Verteiler-Lokalisator
    • Kontakt Dienst
    • Informationen anfordern
    • Careers
      • Jobs
      • <i class="fa fa-chevron-left"></i> Back
    • <i class="fa fa-chevron-left"></i> Back
  • Videos
    • Anfahrtsbeschreibung
    • Video-Broschüren
    • <i class="fa fa-chevron-left"></i> Back
  • Rudolph Standards Lab
  • Laden
    • Cart
    • <i class="fa fa-chevron-left"></i> Back
  • English
  • Türkçe
  • Español
  • Português