Petroleum Refractometer
Petroleum Refractometer Industry Description
The petroleum industry is standardized through ASTM methods, and the key is having a refractometer that meets the specifications of ASTM.. For Refractive Index(RI) measurements this mostly means ASTM D1218 and D1747. Compliance with D1218 is for measurement at temperatures between 20°C and 30°C and is mostly used for light hydrocarbons. D1747 is for measurements up to 100°C and is often used for crude oils and other process streams. ASTM is very strict with temperature as these types of samples generally have a very much larger dn/dt value than the water / sugar samples used in food.
Reasons to Choose Rudolph
- Reflectance style measurement system allows the instrument to measure samples much darker than a traditional Abbe style
refractometer can. - Temperature control allows the instrument to be calibrated with traceable references to meet ISO and similar standards.
- Flat, easy clean, prism means better results even when used by non-laboratory trained operators.
- Compliance with D1218 is for measurement at temperatures between 20°C and 30°C for light hydrocarbons as well as D1747 is for measurements up to 100°C for crude oils
Typical Rudolph Users
- ExxonMobil uses the J457 at 67° C to check a process stream.
- SGS uses Rudolph refractometers for custody transfer checking.
- Sinopec uses the J357 petroleum refractometer for research and development.
Refractometer Selections by Industry
Petroleum Refractometers for the Petro-Chemical Industry.
Seleccionando el refractómetro adecuado para las demandas de la industria petrolera y petroquímica. ¿Mide usted...
|
|
|
Petroleum Refractometer Feature Highlight
La investigación analítica de Rudolph J357 es capaz de controlar la temperatura hasta los 100°C porque tiene un sistema único de control de temperatura dual donde el calor es
aplicado a ambos lados de la muestra.
Sin embargo, todavía hay aplicaciones en las que se necesitan temperaturas superiores a los 100°C. Para acomodar la necesidad de medir por encima de los 100°C, la opción de aumento de la temperatura (TB) fue desarrollada para la Serie de Refractómetro J357.
La opción de aumento de la temperatura (TB) proporciona dos beneficios:
- La temperatura máxima del refractómetro se incrementa de 100°C a 110°C.
- The maximum temperature of the temperature control system is increased to 120°C for a period of 60 minutes. At the end of 60 minutes the temperature control will shut off and the petroleum refractometer will cool down to ambient temperature for a period of 1 hour.
Modelo | Especificación | Características y beneficios |
---|---|---|
![]() |
Rango de medición: 1,26 - 1,7 RI; 0 - 95% Brix Precisión:0,0001 RI; 0,1 Brix Control electrónico de temperatura: Selección de temperatura fija: 20°C y 25°C | El J57WR-UF-SP petroleum refractometer is often combined with Rudolph’s density meter for automated measure of petroleum fuels, oil and waxes. Combining a refractometer with an ECS autosampler eliminates the need for manual loading. |
![]() |
Rango de medición: 1.26 - 1.70 RI; 0 - 95% Brix Precisión:0.00004 RI; 0.03 Brix Control electrónico de temperatura:Selección flexible de temperatura entre 15°C - 100°C; Opción TB: permite 15°C - 110°C con un aumento de una hora a 120°C | Designación: D1747-99![]() |
![]() |
Rango de medición: 1,26 - 1,72 RI; 0 - 100% Brix Precisión: 0,00002 RI; 0,015 Brix Control electrónico de temperatura: Selección flexible de temperatura entre 10°C y 100°C con una reproducibilidad de ±0,01°C. |
Rudolph’s most capable petroleum refractometer. Perfect for today’s highly regulated laboratories offering full 21CFR Part 11 compliance. Rudolph Research is the first manufacturer to offer Smart Measure™ a system that notifies the operator of the quality and status of the sample load, as well as the sample well status. This assists the operator in producing more accurate readings. It documents that the sample was properly loaded. The J457 is available in 3 configurations J457 SC – Standard Bench-top, J457 WC – Wall Mount, and the J457 FC – Factory Configuration. These configurations allow the measurement unit to be isolated from the display unit, thus protecting it from harsh environments and messy spills. |