Petroleum-Refraktometer
Petroleum-Refraktometer Industrie Beschreibung
The petroleum industry is standardised through ASTM methods, and the key is having a refractometer that meets the specifications of ASTM. For Refractive Index(RI) measurements, this mostly means ASTM D1218, D2140, and D1747. Compliance with D1218 is for measurement at temperatures between 20°C and 30°C and is mostly used for light hydrocarbons. D1747 is for measurements up to 100°C and is often used for crude oils and other process streams. ASTM is very strict with temperature, as these types of samples generally have a much larger dn/dt value than the water/sugar samples used in food.
Gründe für die Wahl von Rudolph
- Reflectance style measurement system allows the instrument to measure samples much darker than a traditional Abbe-style refractometer can.
- Durch die Temperaturregelung kann das Gerät mit rückführbaren Referenzen kalibriert werden, um ISO- und ähnliche Normen zu erfüllen.
- Das flache, leicht zu reinigende Prisma sorgt für bessere Ergebnisse, auch wenn es von nicht im Labor geschultem Personal verwendet wird.
- Die Konformität mit D1218 / D2140 gilt für Messungen bei Temperaturen zwischen 20°C und 30°C für leichte Kohlenwasserstoffe sowie D1747 für Messungen bis zu 100°C für Rohöle
Typische Rudolph-Benutzer
- ExxonMobil verwendet das J457 bei 67° C zur Überprüfung eines Prozessstroms.
- SGS verwendet Rudolph-Refraktometer für eichpflichtige Prüfungen.
- Sinopec verwendet das J357 Petroleum-Refraktometer für Forschung und Entwicklung.
Refraktometer-Auswahl nach Industriezweigen
- Essen und Trinken
- Zuckermüllerei, Raffination, Verarbeitung
- Chemisch
- Pharmazeutische und toxikologische Tests
- Erdöl
- Aroma, Duftstoffe, Kosmetika
- Modellvergleichstabellen
- Kalibrierung und Dokumentation
Petroleumrefraktometer für die petrochemische Industrie.
Die Auswahl des richtigen Refraktometers für die Anforderungen der Erdöl- und Petrochemieindustrie. Messen Sie...
|
|
|
Petroleum-Refraktometer Highlight
The Rudolph Research Analytical J357 is able to control temperature to 100°C because it has a unique dual temperature control system where heat is applied to both sides of the sample.


Die Option Temperaturerhöhung (TB) bietet zwei Vorteile:
- Die Höchsttemperatur des Refraktometers wird von 100°C auf 110°C erhöht.
- The maximum temperature of the temperature control system is increased to 120°C for a period of 60 minutes. At the end of 60 minutes, the temperature control will shut off, and the petroleum refractometer will cool down to ambient temperature for a period of 1 hour.
| Modell | Spezifikation | Merkmale und Vorteile |
|---|---|---|
| |
Messbereich: 1,26 - 1,7 RI; 0 - 95% Brix Genauigkeit:0,0001 RI; 0,1 Brix Elektronische Temperaturregelung: Feste Temperaturwahl: 20°C und 25°C | The J57WR-UF-SP petroleum refractometer is often combined with Rudolph’s density meter for automated measurement of petroleum fuels, oil and waxes. Combining a refractometer with an ECS autosampler eliminates the need for manual loading. |
![]() |
Messbereich: 1,26 - 1,70 RI; 0 - 95% Brix Genauigkeit:0,00004 RI; 0,03 Brix Elektronische Temperaturregelung:Flexible Temperaturwahl zwischen 15°C - 100°C; TB-Option: ermöglicht 15°C - 110°C mit einstündiger Erhöhung auf 120°C | Bezeichnung: D1747-99 Standardprüfverfahren für den Brechungsindex von viskosen Materialien 1. Anwendungsbereich 1.1 This test method covers the measurement of refractive indexes, accurate to two units in the fourth decimal place, of transparent and light-colored viscous hydrocarbon liquids and melted solids which have refractive indexes in the range between 1.33 and 1.60, and at temperatures from 80 to 100°C. Temperatures lower than 80°C can be used, provided that the melting point of the sample is at least 10°C below the test temperature. The J357-NDS ist in der Lage, die Temperatur auf 100 °C zu regeln, da es über ein einzigartiges duales Temperaturregelungssystem verfügt, bei dem die Wärme auf beide Seiten einer Probe aufgebracht wird, was den Anforderungen aller ASTM standards. For added flexibility for cloud points occurring closer to 120°C, select the TB option. Please contact the factory for help with this option. |
![]() |
Messbereich: 1,26 - 1,72 RI; 0 - 100% Brix Genauigkeit: 0,00002 RI; 0,015 Brix Elektronische Temperaturregelung: Flexible Temperaturwahl zwischen 10°C und 100°C mit einer Reproduzierbarkeit von ±0,01°C. |
Rudolph’s most capable petroleum refractometer. Perfect for today’s highly regulated laboratories offering full 21CFR Part 11 compliance. Rudolph Research is the first manufacturer to offer Smart Measure™, a system that notifies the operator of the quality and status of the sample load, as well as the sample well status. This assists the operator in producing more accurate readings. It documents that the sample was properly loaded. The J457 is available in 3 configurations: J457 SC – Standard Bench-top, J457 WC – Wall Mount, and the J457 FC – Factory Configuration. These configurations allow the measurement unit to be isolated from the display unit, thus protecting it from harsh environments and messy spills. |




Standardprüfverfahren für den Brechungsindex von viskosen Materialien 1. Anwendungsbereich 1.1 This test method covers the measurement of refractive indexes, accurate to two units in the fourth decimal place, of transparent and light-colored viscous hydrocarbon liquids and melted solids which have refractive indexes in the range between 1.33 and 1.60, and at temperatures from 80 to 100°C. Temperatures lower than 80°C can be used, provided that the melting point of the sample is at least 10°C below the test temperature. The 